The failing component is the system backplane (I/O backplane for 9406-MMA or 9117-MMA).
Use the table below to find the service information for the specified FRU.
Note: After you have replaced the part, make sure to set the enclosure serial number before powering up, otherwise the machine will not IPL. For more information, see "Setting the system enclosure type" in the operations guide for the server.
If the server is a multiple-drawer 9406-MMA or 9117-MMA server and the SRC is a B1xx SRC, use the last byte in word 3 of the primary SRC to determine which backplane to replace:
If you don't have access to word 3 of the primary SRC, you can also determine which backplane to replace by using either of the following methods:
Use the following table to determine the part number for the field replaceable unit (FRU): This ends the procedure.
CCIN or FFC
Type and model
Part number
Description
Location code
8204-E8A
10N9369
System backplane
Un-P1
9406-MMA, 9117-MMA
42R7352
I/O backplane
Un-P1