TWRBKPL

The failing item is the tower card in an I/O unit.

  1. Are you working from the serviceable event view and a card location is listed with this failing item?
    • Yes: Then the listed card location is where the error is located. Continue with the next step.
    • No: Record the bus number value, BBBB, in word 7 of the reference code (see DSA translation). Search for the bus number in the HMC's or operating system's resource and configuration interfaces or the System Configuration Listing to determine which unit contains the failing item. Continue with the next step.
  2. The failing item is built into the I/O backplane of the I/O unit. Use the following table to determine the part number for the field replaceable unit (FRU):

    CCIN or FFC Type and model Part number Description Location code
      5790, 7311-D11 80P6626 I/O backplane Un-P1
    28BE 0595, 5095, 7311-D20 39J0515 I/O backplane Un-P1
      5796, 7314-G30 10N7677 I/O backplane Un-P1
      5094 39J3058 I/O backplane Un-CB1

This ends the procedure.