This MAP handles problems when
the system unit hangs while configuring a resource.
-
Step 0260-1
The last three or four
digits of the SRN following the dash (-) match a failing function code number.
Look
at the part information and find the failing function
code that matches the last three or four digits of your SRN, following the
dash. Record the FRU part number and description (use the first FRU part listed
when multiple FRUs are listed).
The physical location code, AIX(R) location code,
or device name is displayed on the operator panel.
Do you have either
a physical location code or AIX location code displayed?
- No
- Go to Step 0260-4.
- Yes
- Go to Step 0260-2.
-
Step 0260-2
Are there any FRUs
attached to the device described by the physical location code or AIX location code?
- No
- Go to Step 0260-6.
- Yes
- Go to Step 0260-3.
-
Step 0260-3
Remove this kind of
FRU attached to the device described in the location code one at a time. Note
whether the system still hangs after each device is removed. Do this until
you no longer get a hang, or all attached FRUS have been removed from the
adapter or device.
Has the symptom changed?
- No
- Go to Step 0260-4.
- Yes
- Use the location code of the attached device that you removed when the
symptom changed, and go to Step 0260-6.
-
Step 0260-4
Does your system
unit contain only one of this kind of FRU?
- No
- Go to Step 0260-5.
- Yes
- Go to Step 0260-6.
-
Step 0260-5
One of the FRUs of this
kind is defective.
Remove this kind of FRU one at a time. Test the system
unit after each FRU is removed. Stop when the test completes successfully
or when you have removed all of the FRUs of this kind.
Were you able
to identify a failing FRU?
- No
- Go to PFW1540: Problem isolation procedures.
- Yes
- Go to Step 0260-6.
-
Step 0260-6
- Turn off the system unit.
- Exchange the FRU identified by the location code or Step
0260-5.
Is this system capable of running online diagnostics in service
mode?
- No
- Go to Step 02607.
- Yes
- Go to Step 02608.
-
Step 0260-7
- Turn on the system unit.
- Load the standalone diagnostics and refer to Running the online and eServer stand-alone diagnostics.
- Wait until the Diagnostic Operating Instructions display or the system
appears to have stopped.
Are the DIAGNOSTIC OPERATING INSTRUCTIONS displayed?
- NO
- Go to Step 02609.
- YES
- Go to Verifying a repair.
-
Step 0260-8
- Turn on the system unit.
- Load the standalone diagnostics and refer to Running the online and eServer stand-alone diagnostics.
- Wait until the Diagnostic Operating Instructions display or the system
appears to have stopped.
Are the DIAGNOSTIC OPERATING INSTRUCTIONS displayed?
- NO
- Go to Step 0260-9.
- YES
- Go to Verifying a repair.
-
Step 0260-9
Look at the operator
panel display.
Is the number displayed the same as the last three
or four digits after the dash (-) of your SRN?
- NO
- The symptom changed. Check for loose cards, cables, and obvious problems.
If you do not find a problem, go to MAP 0020: Problem determination procedure and
get a new SRN.
- YES
- Go to Step 0260-10.
-
Step 0260-10
Was the FRU you
exchanged an adapter or a planar?
- NO
- Go to Step 0260-11.
- YES
- Go to PFW1540: Problem isolation procedures.
-
Step 0260-11
Was the FRU you
exchanged a device?
- NO
- Go to.
- YES
- Go to Step 0260-12.
-
Step 0260-12
The adapter for the
device may be causing the problem.
- Turn off the system unit.
- Exchange the adapter for the device.
Note:
If the AIX operating system is not used on the
system, start diagnostics from an alternate source.
- Turn on the system unit. If c31 is displayed, follow
the instructions to select a console display.
- Load the standalone diagnostics and refer to Running the online and eServer stand-alone diagnostics.
- Wait until the DIAGNOSTIC OPERATING INSTRUCTIONS display or the system
appears to have stopped.
Are the DIAGNOSTIC OPERATING INSTRUCTIONS displayed?
- NO
- Go to PFW1540: Problem isolation procedures.
- YES
- Go to Verifying a repair.