A Device Concurrent Maintenance display is shown, similar to the following display.
Device Concurrent Maintenance
Type the choices, then press Enter.
Specify either Physical Location or PCI/SCSI location.
Physical Location: U0.1-P1-I4/Z1-A8
OR
PCI/SCSI . . . PCI Bus: PCI Device:
SCSI Channel: SCSI Id: SCSI Lun:
Specify action as 1=Remove device 2=Install device
Action to be performed . . . . . . . . . : 1
Enter a time value between 01 and 19.
Time needed in minutes . . . . . . . . . : 1
Or leave blank and press Enter to cancelThe concurrent maintenance
light indicates that you can remove the disk drive.

A Device Concurrent Maintenance Action display is shown, similar to the following display.
Device Concurrent Maintenance Action
Removal of device:
Location: U0.1-P1-I4/Z1-A8
You have 1 minute to perform the operation
During this time, your system can seem unresponsive
c=Confirm q=CancelA Device Concurrent Maintenance Action In Progress display is shown, similar to the following display.
Device Concurrent Maintenance Action In Progress
Please remove the device located in:
Location: U0.1-P1-I4/Z1-A8