Prepare to remove the disk drive

  1. Log in as root user.
  2. Type iprconfig on the command line of the Linux(R) session and press Enter.

    The IBM(R) Power RAID Configuration Utility display is shown.

  3. Select Analyze log. Press Enter. The Kernel Messages Log display is shown.
    Figure 20. Kernel Messages Log
                                          Kernel Messages Log
    
    
    Select one of the following:
    
        1. View most recent ipr error messages
        2. View ipr error messages
        3. View all kernel error messages
        4. View iprconfig error messages
        5. Set root kernel message log directory
        6. Set default editor
        7. Restore defaults
        8. View ipr boot time messages
    
    
    Selection:
    
    e=Exit
  4. Select View most recent ipr error messages from the Kernel Messages Log display. Press Enter.
  5. Find the entry in the log for the disk drive you want to replace.
  6. Record the location information for the disk drive.
    Note:
    The location information has the form of 2:0:8:0. In this example, 2 is the SCSI host number, 0 is the SCSI bus, 8 is the SCSI target ID, and 0 is the LUN (logical unit).
  7. Return to the command line.
  8. Type the following:

    ls -ld /sys/class/scsi_host/host#/device

    where # is the SCSI host number. Press Enter.

  9. Record the PCI location information.
    Note:
    The PCI location information has the form of 61:01:0:2.
  10. Type iprconfig on the command line and press Enter.

    The IBM Power RAID Configuration Utility display is shown.

  11. Select Display hardware status from the IBM Power RAID Configuration Utility display. Press Enter.

    The Display Hardware Status display is shown.

    Figure 21. Example Display Hardware Status
                                 Display Hardware Status
    
    Type option, press Enter.
      1=Display hardware resource information details
    
    OPT Name   PCI/SCSI Location          Description               Status
    --- ------ -------------------------- ------------------------- ----------------
               0000:01:01.0.0/            PCI-X SCSI Adapter        Operational
               0000:41:01.0.1/            PCI-X SCSI Adapter        Operational
        sda    0000:41:01.0.1/0:3:0       Physical Disk             Active
        sdb    0000:41:01.0.1/0:4:0       Physical Disk             Active
        sdc    0000:41:01.0.1/0:8:0       Physical Disk             Active
        sdd    0000:41:01.0.1/1:3:0       Physical Disk             Active
        sde    0000:41:01.0.1/1:4:0       Physical Disk             Active
        sdf    0000:41:01.0.1/1:5:0       Physical Disk             Active
               0001:61:01.0.2/            PCI-X SCSI RAID Adapter   Operational
        sdg    0001:61:01.0.2/0:3:0       Physical Disk             Active
               0001:61:01.0.2/0:6:0       Advanced Function Disk    Active
        sdi    0001:61:01.0.2/0:9:0       Physical Disk             Active
        sdh    0001:61:01.0.2/255:0:0     RAID 10 Disk Array        Failed
               0001:61:01.0.2/0:4:0       RAID 10 Array Member      Failed
               0001:61:01.0.2/0:5:0       RAID 10 Array Member      Failed
    
    e=Exit   q=Cancel   r=Refresh   t=Toggle
  12. Look for the disk drive at the PCI location you recorded. The disk drive might have a Failed status.
  13. If the disk drive you want to replace is unprotected or in use, move the data from the disk drive before continuing with this procedure.

    For information, see the PCI-X SCSI RAID Controller Reference Guide for Linux.

    This guide is available from the SCSI PCI Adapters Web page at http://publib.boulder.ibm.com/infocenter/pseries/v5r3/index.jsp?topic=/com.ibm.pseries.doc/hardware_docs/scsipciadapters.htm.

  14. Type option 1 (Display hardware resource information details) next to the disk drive you want to replace. Press Enter.

    A Disk Hardware Resource Information Details display similar to the following is shown.

    Figure 22. Example Disk Hardware Resource Information Details display
                     Disk Unit Hardware Resource Information Details
    
    
    Manufacturer . . . . . . . . . . . . . . : IBM
    Product ID . . . . . . . . . . . . . . . : ST336607LC
    Firmware Version . . . . . . . . . . . . : 43353048 (C50H)
    Serial Number. . . . . . . . . . . . . . : 00006719
    Capacity . . . . . . . . . . . . . . . . : 36.40 GB
    Resource Name. . . . . . . . . . . . . . : /dev/sdd
    
    Physical location
    PCI Address. . . . . . . . . . . . . . . : 0001:50:01.0
    SCSI Host Number . . . . . . . . . . . . : 2
    SCSI Channel . . . . . . . . . . . . . . : 0
    SCSI Id. . . . . . . . . . . . . . . . . : 4
    SCSI Lun . . . . . . . . . . . . . . . . : 0
    
    Extended Details
    FRU Number . . . . . . . . . . . . . . . : 00P2676
                                                                            More...
    Press Enter to Continue
    
    e=Exit   q=Cancel   f=PageDn   b=PageUp
  15. Record the physical location information.
  16. Return to the IBM Power RAID Configuration Utility display.
  17. Continue with the procedure to Remove the disk drive.