Verifying a repair

Use this information to verify hardware operation after making repairs to the system. Choose the operating system that you are working with:

Choose from the following:

  1. Power on the server and all attached I/O enclosures.

    Did all the enclosures power on?

    No Yes
    V Go to Step 3.
  2. Choose from the following:
    • If the original problem was that an enclosure would not power on and you have another FRU to replace, go to Locating FRUs to locate the next FRU.
    • If the next FRU in the FRU list is an isolation procedure, perform the isolation procedure.
    • If the original problem was that an enclosure would not power on and you have an isolation procedure to perform, perform the isolation procedure.
    • If the original problem was that an enclosure would not power on and there are no more FRUs or isolation procedures in the FRU list, invoke your support structure.
    • If you have a new problem, go to Problem Analysis. and perform problem analysis.
  3. Load the operating system.

    Did the operating system load successfully?

    No Yes
    V Go to Step 5.
  4. Choose from the following:
    • If the original problem was that the operating system would not load and you have another FRU to replace, go to Locating FRUs to locate the next FRU.
    • If the next FRU in the FRU list is an isolation procedure, perform the isolation procedure.
    • If the original problem was that the operating system would not load and you have an isolation procedure to perform, perform the isolation procedure.
    • If the original problem was that the operating system would not load and there are no more FRUs or isolation procedures in the FRU list, invoke your support structure.
    • If you have a new problem, go to Problem Analysis.
  5. Choose from the following: