Verify that the fix installed correctly
  1. Ensure that the managed systems and power frames (if you have a model 575 or 59x server) are in the correct state.
    1. From the HMC, select Server and Partition.
    2. Select Server Management and ensure that the State is Power Off, Standby, or Operating.
    3. If you have a model 575 or 59x server, select Frame Management and ensure that the state is Standby.
  2. From the HMC, expand the Licensed Internal Code Maintenance folder.
  3. Click the Licensed Internal Code Updates icon.
  4. In the Contents area, click Change Licensed Internal Code.
  5. In the Target Object Selection window, click the target system, and click OK. The target is the managed system for which you want to verify the firmware level.
  6. In the Change Licensed Internal Code window, select View system information, and click OK.
  7. In the Specify LIC Repository window, select None, and click OK. A window is displayed that shows system information for the target system.
  8. Verify that the installed and activated levels of firmware match the fix that you installed.
  9. If the installed and activated levels of firmware do not match the fix that you installed, perform the following steps:
    1. Check the network connection on the HMC.
    2. Retry the update using a different repository.
    3. If the problem persists, contact your next level of support.