FSPSP38

The system has detected an error within the JTAG path. If the FRU replaced before this procedure did not correct the problem, perform the following:

Refer toLocating FRUs for instructions on replacing any FRUs called out by this procedure.

  1. Was the FRU called out before this procedure a Memory DIMM (Un-P2-C1-Cx or Un-P2-C2-Cx)?
  2. Replace the Service Processor (Un-P1-C11) from the same drawer as the Memory DIMM.
  3. Perform a slow boot.
  4. Does the problem persist?
  5. Replace the Processor Card (Un-P2-C1 or Un-P2-C2) on which you previously replaced DIMMs.
  6. Perform a slow boot.
  7. Does the problem persist?
  8. Replace the System Backplane (Un-P1) from the same drawer as the Memory DIMM.
  9. Perform a slow boot. This ends the procedure.
  10. Was the FRU called out before this procedure a Processor Card (Un-P2-C1 or Un-P2-C2) or GX Adapter Card (Un-P1-C8 or Un-P1-C9)?
  11. Replace the Service Processor (Un-P1-C11) from the same drawer as the Processor Card or GX Adapter Card.
  12. Perform a slow boot.
  13. Does the problem persist?
  14. Replace the System Backplane (Un-P1) from the same drawer as the Processor Card or GX Adapter Card.
  15. Perform a slow boot. This ends the procedure.
  16. Was the FRU called out before this the System Backplane (Un-P1)?
  17. Replace the Service Processor (Un-P1-C11) from the same drawer as the System Backplane.
  18. Perform a slow boot. This ends the procedure.