- Is the reference code 1xxx 1C10, 1C11, 1C12, 1C13, 1C14, or 1C15?
- Yes: Continue with the next step.
- No: Go to step 5.
- Is the reference code 1xxx 1C10, 1C11, 1C13, 1C14, or 1C15?
- No: Continue with the next step.
- Yes: Go to step 4.
-
Perform the following:
- Power off the system.
- Replace one of the memory DIMMs on the processor cards (see Locating FRUs).
- Power on the system.
- Has this resolved the problem?
- No: Continue with step 3e.
- Yes: This ends the procedure.
-
Have you replaced all of the DIMMs?
- No: Repeat step 3 and
replace the next memory DIMM.
- Yes: Go to step 4.
-
Perform the following:
- Power off the system.
- Replace one of the processor cards. For 1xxx 1C11 or 1C15, start
with processor card 2. See Locating FRUs.
- Power on the system.
- Has this resolved the problem?
- No: Continue with step 4e.
- Yes: This ends the procedure.
-
Have you replaced all of the processor cards?
- No: Repeat step 4 and
replace the next processor card.
- Yes: Go to step 8.
-
Perform the following:
- Power off the system and disconnect the ac power cable from
the unit you are working on.
- Disconnect all of the I/O devices (tape, diskette, optical,
and disk units) from the unit you are working on by sliding them partially
out of the unit.
- Remove and label all cards (for example, PCI adapters, memory
DIMMs, GX adapter(s), RIO/HSL and RAID cards if installed).
- Reconnect the ac power cable to the unit you are working on.
- Power on the system.
Does a power reference code occur?
- Yes: Continue with the next step.
- No: Go to step 10.
-
Perform the following:
- Power off the system.
- Replace one of the system fans (see Locating FRUs).
- Power on the system.
Does a power reference code occur?
- Yes: Continue with the next step.
- No: The fan you just replaced was the failing item.
This
ends the procedure.
- Have you tried replacing all of the fans?
- Yes: Reinstall all of the fans you replaced in
step 6 and continue with
the next step.
- No: Perform the following:
- Power off the system.
- Reinstall the fan that you just removed in step 6 to
its original location.
- Repeat step 6.
-
Perform the following:
- Power off the system.
- Replace one of the voltage regulator cards. See Locating FRUs
- Power on the system.
Does a power reference code occur?
- Yes: Continue with the next step.
- No: The voltage regulator card you just replaced
was the failing item.
This ends the procedure.
- Have you tried replacing all of the voltage regulator cards?
- Yes: Replace the regulator distribution connection
backplane P2 (see Locating FRUs). This
ends the procedure.
- No: Perform the following:
- Power off the system.
- Reinstall the voltage regulator card that you just removed in step 8 to its original location.
- Repeat step 8.
-
Perform the following:
- Power off the system.
- Reinstall all of the cards (PCI adapters, memory DIMMs, GX adapter(s),
RIO/HSL and RAID cards ) you removed in step 5 to
their original locations.
- Power on the system.
Does a power reference code occur?
- Yes: Continue with the next step.
- No: Go to step 13.
-
Perform the following:
- Power off the system.
- Disconnect one of the cards you reinstalled in step 10.
- Power on the system.
Does a power reference code occur?
- Yes: Continue with the next step.
- No: Exchange the last card you disconnected in
this step (see Locating FRUs). This
ends the procedure.
- Have you disconnected all of the cards?
- No: Repeat step 11.
- Yes: Reinstall all of the parts you have removed
or exchanged in this procedure and return to Starting a Service Call. This
ends the procedure.
-
Perform the following:
- Power off the system.
- Reconnect all of the I/O devices (tape, diskette, optical, and
disk units) that you disconnected in step 5.
- Power on the system.
Does a power reference code occur?
- Yes: Continue with the next step.
- No: The problem has been resolved. This
ends the procedure.
-
Perform the following:
- Power off the system.
- Disconnect one of the I/O devices (tape, diskette, optical,
and disk units) that you reconnected in step 13.
- Power on the system.
Does a power reference code occur?
- Yes: Continue with the next step.
- No: Exchange the last I/O device you disconnected
in this step (see Locating FRUs). This
ends the procedure.
- Have you tried disconnecting all of the I/O devices?
- No: Repeat step 14.
- Yes: Reinstall all of the parts you have removed
or exchanged in this procedure and contact your next level of support.This
ends the procedure.