IOPIP13

Use this procedure to isolate problems on the interface between the I/O card and the storage devices.

The unit reference code (part of the SRC that sent you to this procedure) indicates the SCSI bus that has the problem:

Unit reference code (URC) SCSI bus
3100 0
3101 1
3102 2
3103 3
  1. If the system has logical partitions, perform this procedure from the logical partition that reported the problem. To determine if the system has logical partitions, go to Determining if the system has logical partitions.
  2. Were you performing an IPL from removable media (IPL type D) when the error occurred?
  3. Perform the following steps:
    1. Look in the service action log (see Using the Service Action Log) for other errors logged at or around the same time as the 310x SRC.
    2. If no entries appear in the service action log, use the product activity log (see Using the product activity log).
    3. Use the other SRCs to correct the problem before performing an IPL.
    4. Contact your next level of support as necessary for assistance with SCSI bus problem isolation.
    5. If the problem is not corrected, continue with the next step.
  4. Perform an IPL to DST. See Performing an IPL to DST. Does an SRC appear on the control panel?
  5. Does one of the following displays appear on the console?
  6. Are all of the reference codes 0000? On some of the displays, you must press F11 to display reference codes.
  7. Is the SRC the same one that sent you to this procedure?
  8. Perform the following:
    1. Power off the system or the expansion tower. See Powering on and powering off for details.
    2. Find the I/O card identified in the failing item list.
    3. Remove the I/O card and install a new I/O card. See Removing and Replacing FRUs. This item has the highest probability of being the failing item.
    4. Power on the system or the expansion tower.

    Does an SRC appear on the control panel?

  9. Does one of the following displays appear on the console?
  10. Is the reference code the same one that sent you to this procedure?
  11. Look at the product activity log. See Using the product activity log for details. Is an SRC logged as a result of this IPL?
  12. Is the SRC or reference code the same one that sent you to this procedure?
  13. The original I/O card is not the failing item. Install the original I/O card by doing the following:
    1. Power off the system or the expansion tower. See Powering on and powering off for details.
    2. Remove the I/O card you installed in step 8 of this procedure and install the original I/O card.
      Note:
      Do not power on the system or the expansion unit now.

    A device connected to the I/O card could be the failing item. Go to IOPIP16, step (9) to continue isolating the problem. This ends the procedure.