IOPIP18

Use this procedure to isolate problems that are associated with SCSI bus configuration errors and device task initialization failures.

  1. If the system has logical partitions, perform this procedure from the logical partition that reported the problem. To determine if the system has logical partitions, go to Determining if the system has logical partitions before continuing with this procedure.
  2. Perform an IPL to DST. See Performing an IPL to DST.

    Does an SRC appear on the control panel?

  3. Does one of the following messages appear in the list?
  4. Look at the product activity log (see (Log) for details).

    Is an SRC logged as a result of this IPL?

  5. Record the SRC.

    Is the SRC the same one that sent you to this procedure?

  6. Determine the device unit reference code (URC) from the SRC. If the Disk Configuration Error Report, the Disk Configuration Attention Report, or the Disk Configuration Warning Report display appears on the console, the device URC is displayed under Reference Code. This is on the same line as the missing device.

    Is the device unit reference code 3020?

  7. The possible failing items are FI codes FI01105 (90%) and FI01112 (10%).

    Find the device unit address from the SRC. Use this information to find the physical location of the device. Record the type and model numbers to determine if the addressed I/O card supports this device.

    Is the device given support on your system?

  8. Perform the following steps:
    1. Remove the device.
    2. Perform an IPL to DST. See Performing an IPL to DST.

    Does this correct the problem?