IOPIP26

Use this procedure to correct the problem when the I/O card recognizes that the attached disk unit must be initialized and formatted.

You were sent to this procedure from URC 9092.

  1. If the system has logical partitions, perform this procedure from the logical partition that reported the problem. To determine if the system has logical partitions, go to Determining if the system has logical partitions before continuing with this procedure.
  2. Have any other I/O card or device SRCs occurred at about the same time as this error?
  3. Access SST/DST by doing one of the following:
  4. Did you perform a D IPL to get to DST?
  5. Perform the following steps:
    1. Access the Product Activity Log and display the SRC that sent you here. The direct select address (DSA) of the I/O card is in the format BBBB-Cc-bb:
      • BBBB = hexadecimal offsets 4C and 4D
      • Cc = hexadecimal offset 51
      • bb = hexadecimal offset 4F

        The unit address of the I/O card is hexadecimal offset 18C through 18F.

    2. A formatted display of hexadecimal information for Product Activity Log entries is not available. In order to interpret the hexadecimal information, see More information from hexadecimal reports. Record the addresses that are not 0000 0000 for all devices listed.
    3. Continue with the next step.
  6. See Physical Locations and find the diagram of the system unit, or the expansion unit. Then find the following:

    Have you determined the location of the I/O card and the devices that are causing the problem?

  7. Do you want to continue using these devices with this I/O card?
  8. Initialize and format the disk units by performing the following steps:
    Attention: Data on the disk unit will be lost.
    1. Access SST or DST.
    2. Select Work with disk units.

      Did you get to DST with a Type D IPL?

      • Yes: Continue with the next step.
      • No: Select Work with disk unit recovery -> Disk unit problem recovery procedures. Then continue with the next step.
    3. Select Initialize and format disk unit for each disk unit. When the new disk unit is initialized and formatted, the display shows that the status is complete. This may take 30 minutes or longer. The disk unit is now ready to be added to the system configuration. This ends the procedure.