LPRIP01

Use this procedure to isolate the problem when LPAR configuration data does not match the current system configuration.

  1. Is there only one B6005311 error logged, and is it against the load source device for the partition, in either the Primary or a secondary partition?
  2. Was the load source disk unit migrated from another partition within the same system?
  3. The reporting partition is a secondary partition.

    Since the last IPL of the reporting partition, have one of the following occurred?

  4. Are there multiple B600 5311 SRCs logged in the same partition?
  5. Is the resource for one of the B600 5311 SRCs the load source device and are all of the other B600 5311 entries for resources which are non-configured disk units?
    Note:
    To determine if a disk unit is a non-configured disk unit, refer to the "Work with disk unit options" section in the "DST options" section of the "DST chapter" in the iSeries(TM) Service Functions information.
  6. Was the load source disk unit migrated from another partition within the same system?
  7. The reporting partition is a secondary partition.

    Since the last IPL of the reporting partition, have one of the following occurred:

  8. One or more B600 5311 SRCs have been logged in the same partition.

    Do all of the B600 5311 errors have a resource which is a non-configured disk unit in the partition?

    Note:
    To determine if a disk unit is a non-configured disk unit, refer to the "Work with disk unit options" section in the "DST options" section of the "DST chapter" in the iSeries Service Functions information.
  9. Were any disk unit resources associated with the B600 5311 SRCs added to the partition, since the last IPL of this partition?
  10. None of the resources that are associated with the B600 5311 SRCs are disk units that were added to the partition since the last IPL of the partition.

    Has a scratch install recently been performed on the partition that is reporting the error(s)?

  11. If a scratch install was not performed, was the clear configuration data option recently used to discontinue LPAR use?
  12. Perform the following to clear non-configured disk unit configuration data:
    1. Go to SST/DST in the partition and select Work with system partitions -> Recover configuration data -> Clear non-configured disk unit configuration data.
    2. Select each unit in the list which is new to the system and press Enter.
    3. Continue the system IPL. This ends the procedure.
  13. Was the load source device previously mirrored before the scratch install?
  14. Perform the following to clear the old configuration data from the disk unit that was mirroring the old load source disk
    1. Go to SST/DST in the partition and select Work with system partitions -> Recover configuration data -> Clear non-configured disk unit configuration data.
    2. Select the former load source mirror in the list and press Enter.
  15. Is the Primary partition reporting the B600 5311 error(s)?