MABIP52

This procedure will isolate a failing PCI card from a reference code when the system or logical partition will not IPL.

Attention: The remove and replace procedure of all FRUs in this procedure must be performed using "Dedicated Maintenance".
  1. Determine the PCI bridge set (multi-adapter bridge domain) by performing the following:
    1. Record the bus number (BBBB), the multi-adapter bridge number (C) and the multi-adapter bridge function number (c) from the Direct Select Address (DSA) in word 7 of the reference code. See DSA translation for help in determining these values.
    2. Use the bus number that you recorded and the System Configuration Listing (or ask the customer) to determine what frame the bus is in.
    3. Record the frame type where the bus is located.
    4. The PCI bridge set is the group of card positions controlled by the same multi-adapter bridge on the bus that you recorded. Use the System Configuration Listing, the card position table for the frame type that you recorded, the bus number, and the multi-adapter bridge number to determine the PCI bridge set where the failure occurred.
    5. Using the card position table, record the PCI bridge set card positions.
    6. Examine the PCI bridge set in the frame, and record all the positions with IOA cards installed in them.
  2. Are there any IOPs in the PCI bridge set identified in step 1?
  3. Replace the IOPs and IOAs in the bridge set one at a time until the problem is resolved.

    Was the problem resolved?

  4. Perform the following:
    1. Power off the system or partition.
    2. Remove all the IOA cards in the PCI bridge set identified in step 1. Be sure to record the card position of each IOA so that you can reinstall it in the same position later. To determine the remove and replace procedures for the IOAs, go to Locating FRUs.
    3. Power on the system or partition.

      Does the reference code or failure that sent you to this procedure occur?

      No:
      Power off the system or partition and continue with the next step.
      Yes:
      Continue with step 6.
  5. Reinstall, in its original position, one of the IOAs and power on the system or partition. Does the reference code or failure that sent you to this procedure occur?
    Yes:
    The IOA that you just installed is the failing FRU. Replace the IOA.This ends the procedure.
    No:
    • If a different SRC occurs, Perform problem analysis and follow the service procedures for the new reference code. This ends the procedure.
    • If no SRC occurs and there are more IOAs to install, power off the system or partition and repeat this step.
    • If no SRC occurs and there are no more IOAs to install, the problem is intermittent; contact your next level of support. This ends the procedure.
  6. Perform the following:
    1. Power off the system or partition
    2. Locate the card position table for the frame type that you recorded.
    3. Using the multi-adapter bridge number that you recorded, search for the multi-adapter bridge function number "F" in the card position table to determine the card position of the multi-adapter bridge's FRU.

      Is the multi-adapter bridge's FRU a FRU that you have already exchanged?

      No:
      Continue with the next step.
      Yes:
      Call you next level of support. This ends the procedure.
  7. Perform the following:
    1. Exchange the multi-adapter bridge's FRU at the card position that you determined for it. See Locating FRUs to determine the correct remove and replace procedure.
    2. Install all IOAs in their original positions.
    3. Power on the system or partition.

    Does the reference code or failure that sent you to this procedure occur?

    No:
    Go to Verifying a repair. This ends the procedure.
    Yes:
    Call your next level of support. This ends the procedure.