OPCIP03

Use this procedure to isolate a bringup failure with Operations Console.

DANGER
When working on or around the system, observe the following precautions:

Electrical voltage and current from power, telephone, and communication cables are hazardous. To avoid a shock hazard:

Use this procedure to isolate an Operations Console bringup failure when the SRC on the panel is A6xx5008 or B6xx5008. If you are not using the Operations Console, see A6005004. This procedure only works with cable-connected and LAN configurations. It is not valid for dial connected configurations.

  1. If the system has logical partitions, perform this procedure from the logical partition that reported the problem. To determine if the system has logical partitions, go to Determine if the system has logical partitions before continuing with this procedure.
  2. Is the SRC on the panel A6xx5008 or B6xx5008?
  3. Are words 17, 18, and 19 all equal to 00000000?
  4. Is word 17 equal to 00000002?
  5. Is word 17 equal to 00000004?
  6. Are words 13, 14 and 15 all equal to 00000000?
  7. Is word 13 equal to 00000003?
  8. Is word 13 equal to 00000004?