When working on or around the system, observe
the following precautions:
Electrical voltage and current from power, telephone,
and communication cables are hazardous. To avoid a shock hazard:
- Connect power to this unit only with the IBM provided
power cord. Do not use the IBM provided power cord
for any other product.
- Do not open or service any power supply assembly.
- Do not connect or disconnect any cables or perform installation, maintenance,
or reconfiguration of this product during an electrical storm.
- The product might be equipped with multiple power cords. To remove all
hazardous voltages, disconnect all power cords.
- Connect all power cords to a properly wired and grounded electrical outlet.
Ensure that the outlet supplies proper voltage and phase rotation according
to the system rating plate.
- Connect any equipment that will be attached to this product to properly
wired outlets.
- When possible, use one hand only to connect or disconnect signal cables.
- Never turn on any equipment when there is evidence of fire, water, or
structural damage.
- Disconnect the attached power cords, telecommunications systems, networks,
and modems before you open the device covers, unless instructed otherwise
in the installation and configuration procedures.
- Connect and disconnect cables as described in the following procedures
when installing, moving, or opening covers on this product or attached devices.
To
Disconnect:
- Turn off everything (unless instructed otherwise).
- Remove the power cords from the outlets.
- Remove the signal cables from the connectors.
- Remove all cables from the devices
To Connect:
- Turn off everything (unless instructed otherwise).
- Attach all cables to the devices.
- Attach the signal cables to the connectors.
- Attach the power cords to the outlets.
- Turn on the devices.
(D005)
Use this procedure
to isolate an Operations Console bringup failure when the SRC on the panel
is A6xx5008 or B6xx5008. If you are not using the Operations Console, see
A6005004. This procedure only works with cable-connected and LAN configurations.
It is not valid for dial connected configurations.