Use this procedure to service a PCI card.
| You may service a PCI adapter concurrently or nonconcurrently.
Will you be doing a concurrent repair? |
| No | Yes | |
|---|---|---|
| V | Go to ***. |
|
The component will not be serviced concurrently. If this system is powered on, power it off before continuing. If possible, shut down any running applications and the operating system before powering off the system. Once the system is powered off, remove all power cords from all of the processor enclosures starting with the primary processor enclosure (topmost) and then each secondary enclosure working from top to bottom. |
![]() |
|
Open the back rack door. |
|
![]() |
|
![]() |
| Select PCI Adapter type |
![]() |
| Select the type of PCI Adapter being serviced: | ||
|---|---|---|
| Long Adapter (A) | Medium Adapter (B) | Short Adapter (C) |
| V | Go to step 8. | Go to step 9. |
|
Unlock the retainers (A) by rotating them away from the card. |
![]() |
| Go to step 10. |
|
![]() |
| Go to step 10. |
|
![]() |
|
![]() |
|
![]() |
| Select PCI Adapter type |
![]() |
| Select the type of PCI Adapter being serviced: | ||
|---|---|---|
| Long Adapter (A) | Medium Adapter (B) | Short Adapter (C) |
| V | Go to step 14. | Go to step 15. |
|
![]() |
| Go to step 16. |
|
![]() |
| Go to step 16. |
|
![]() |
|
![]() |
|
![]() |
|
Close the back rack door. |
|
If you removed the power cords, reinstall the power cords for all of the processor enclosures. Install the cords in the following order:
|
![]() |
| Go to Verifying a repair. |
|
If you are doing a concurrent repair using AIX, go to Remove and replace a PCI adapter contained in a cassette in the system with the power on in AIX. If you are doing a concurrent repair using Linux, go to Remove and replace a PCI adapter contained in a cassette in the system with the power on in Linux. |