Use either the advanced system management interface (ASMI) or the
control panel to display and change the configuration ID.
If you are using the ASMI, refer to the operations guide for your system
and use the instructions for Changing system configuration. Use Table 35 to find
the correct configuration ID.
If you are using the control panel continue with the next step.
Perform the following to display the configuration ID:
Attention: The system or unit that will display the ID must be powered
off with ac power applied.
Notes:
If you have just restored power to the system, the service processor must
come back up to standby before control panel functions will work properly.
Bringing the service processor back up to standby takes a few minutes after the
panel appears to be operational.
You must have the panel in manual mode to access function 7 options.
Select function 07 on the system control panel. Press
Enter (07** will be displayed).
Use the arrow keys to increment/decrement to subfunction A8. 07A8 will be displayed. Press Enter (07A8 00 will
be displayed).
Use the arrow keys to increment/decrement to the first byte
of the unit address (usually 3C) for the box you want to
check. 07nn will be displayed, where nn is
the first byte of the unit address.
Press Enter (073C 00, for example, will
be displayed).
Use the arrow keys to increment/decrement to the second byte
of the unit address (usually 01, 02, etc for I/O expansion units) for the
box you want to check. 07nn will be displayed,
where nn is the second byte of the unit address (0701,
for example, for a unit). Press Enter (0701 00, for
example, will be displayed).
Note:
The display on the addressed I/O expansion
unit being addressedshould be blinking on and off while displaying the configuration
ID as the last two characters of the bottom line.
Use the following table to check the unit configuration ID.
Table 35. Unit Configuration IDs
Model or expansion unit
Configuration ID
5088 and 0588
89
5094 and 5294
8A
5095 and 0595
8B
7311-D11, 5790
88
7311-D20
8C
7314-G30, 5796
8D
Is the correct configuration ID displayed for the tower selected?
Select function 07 on the system control panel. Press Enter
(07** will be displayed).
Use the arrow keys to increment/decrement to subfunction A9
(07A9 will be displayed). Press Enter (07A9
00 will be displayed).
Use the arrow keys to increment/decrement to the first byte
of the unit address (usually 3C) for the box that you want
to change. 07nn (073C,
for example) will be displayed, where nn is the first
byte of the unit address. Press Enter (073C 00, for
example, will be displayed).
Use the arrow keys to increment/decrement to the second byte
of the unit address (usually 01, 02, etc for I/O Expansion units) for the
box you want to check. 07nn will be displayed,
where nn is the second byte of the unit address (01,
for example, for a unit). Press Enter (0701 00, for
example, will be displayed).
Note:
The display on the addressed I/O expansion
unit will be blinking on and off.
Use the arrow keys to increment/decrement to the correct configuration
ID (refer to Table 35). 07xx will
be displayed where xx is the configuration ID.
Press Enter (07xx 00 will be displayed).
After 20 to 30 seconds, the display on the addressed I/O expansion unit will
stop blinking and return to the normal display format.
Note:
To
return the panel to normal display, scroll to 07** and press Enter.
Continue with the next step.
Power on the system. Do you still get SRC 1xxxx84D0 or 1xxxx840E?
No:
This ends the procedure.
Yes:
Continue with the next step.
Perform the following:
Power off the system.
Exchange the SPCN card in the failing frame. This ends the procedure.