Instructions for model 285 and 52A
- Is the reference code 1xxx 2631?
- No: Continue with the next step.
- Yes: The voltage regulator for 1.5V is the failing
item and needs to be replaced (see Locations
-- Model 285 and 9131-52A to
locate and replace the regulator). This ends the procedure.
- Is the reference code 1xxx 2632?
- Is the reference code 1xxx 2636 or 2637?
- No: Return to the Starting a Service Call. This
ends the procedure.
- Yes: The 1.2V voltage regulator is the failing
item and needs to be replaced (see Locations
-- Model 285 and 9131-52A.
If you have a 2-way processor, you will have two 1.2V voltage regulators,
both of which will need to be replaced.
- Does the problem persist?
- No: This ends the procedure.
- Yes: Replace the system backplane (see Locations -- Model 285 and 9131-52A). This ends