PWR1918
Instructions for the 9117-MMA
- Is the reference code 1xxx 8450?
- No: Continue with the next step.
- Yes: You have fewer voltage regulator cards than
processor cards. Add another regulator card in the next empty position. This
ends the procedure.
- Is the reference code 1xxx 8451?
- No: Continue with the next step.
- Yes: You have too few voltage regulator cards
installed. Add another regulator card in the next empty position. This
ends the procedure.
- Is the reference code 1xxx 1611, 1612, or 1613?
- No: Continue with the next step.
- Yes: Voltage regulator 1 is the failing item and
needs to be replaced. This ends the procedure.
- Is the reference code 1xxx 1621, 1622, or 1623?
- No: Continue with the next step.
- Yes: Voltage regulator 2 is the failing item and
needs to be replaced. This ends the procedure.
- Is the reference code 1xxx 1631, 1632, or 1633?
- No: Continue with the next step.
- Yes: Voltage regulator 3 is the failing item and
needs to be replaced. This ends the procedure.
- Is the reference code 1xxx 2602?
-
Perform the following:
- Remove one of the voltage regulator cards that you have not
already removed in this procedure and replace it with a new one.
- Power on the system (see Powering on and powering off).
Does reference code 1xxx 2602 appear again?
- Yes: Continue with the next step.
- No: The voltage regulator card that you replaced
was the failing item. This ends the procedure.
- Have you replaced all of the voltage regulator cards?
- Yes: Replace the regulator distribution connection
backplane (P2). This ends the procedure.
- No: Reinstall the original regulator card, and
then repeat step 7.