Workstation adapter console isolation procedure

Contains the procedure necessary to isolate a failure that is detected by the workstation adapter console.

Use this procedure when no display is available with which to perform online problem analysis.

Note:
If you are using a PC, you must install an emulation program.

Read all safety procedures before servicing the system. Observe all safety procedures when performing a procedure. Unless instructed otherwise, always power off the system or expansion tower where the FRU is located, see Powering on and powering off before removing, exchanging, or installing a field-replaceable unit (FRU).

DANGER
When working on or around the system, observe the following precautions:

Electrical voltage and current from power, telephone, and communication cables are hazardous. To avoid a shock hazard:

Read and understand the following service procedures before using this section:

Note:
If the console has a keyboard error, there may be a K on the display. See the workstation service information for more information.
  1. If the system has logical partitions, perform this procedure from the logical partition that reported the problem. To determine if the system has logical partitions, go to Determining if the system has logical partitions.
  2. Ensure that your workstation meets the following conditions:

    Did you find a problem with any of the conditions listed above?

  3. Perform the following to make dedicated service tool (DST) available:
    1. If there is an alternative console, ensure that it is powered on.
    2. Ensure that Manual mode on the control panel is selected.
    3. Select function 21, Make DST Available on the control panel, and press Enter.

    Does a display appear on either the console or any alternative console?

  4. Do you have SRC A600 5001, A600 5004, A600 5007, or B075 xxxx (where xxxx is any value)?
  5. Does SRC 6A59 5007 occur?
  6. Did SRC A600 5001, A600 5004, or 6A59 5008 occur?