| B88 |
9117-MMA |
|
Generic SCSI I/O controller
Notes:
- If the failing FRU for this FFC is PCI(x), where x is the PCI bus number, 0, 1, ..., refer to FFC 221.
- Use the location code to identify the failing FRU. Determine if the failing FRU is integrated on the system board. If the failing FRU is integrated use FFC 221. If the failing FRU is not integrated replace the FRU identified by its description that is shown with the location code for SCSI and SCSI-2 adapter. Choose the FFC for the appropriate SCSI I/O controller.
- Check the SCSI controller fuse or PTC resistor before exchanging the system board. Refer to SCSI-2 Single-Ended Adapter PTC Failure Isolation Procedure in SCSI service hints.
- Check that the SCSI disable jumper is in the enabled position.
- Check the FRU number of the installed external terminator: Low density - 51G7736 High density - 51G7737
|
|