FWPCI2

If you receive FWPCI2 symbolic FRU perform the following procedure.

  1. If the location code identifies a slot:
    1. Check for adapter firmware updates. Apply the update if one is available.
    2. Check the cabling to the adapter (in particular, the adapters that have serial ports). Serial ports might require null modems or special cabling configurations to avoid connecting driver outputs together. This may create a PCI power problem and force the adapter to be de-configured.
    3. Use the hot plug service aid to re-seat the adapter specified by the location code. If re-seating the adapter fixes the problem, perform the repair checkout procedure. If the problem is not resolved, go to the next step.
    4. Use the hot plug task to move the adapter to another slot (behind another PCI bridge). The PCI Adapter Placement document, order number SA76-0090, identifies the PCI Host Bridges (PHB) and associated slots.
  2. If the adapter is successfully re-configured in the new slot (behind another PCI host bridge), the slot in which the adapter was originally plugged is bad. Replace the I/O backplane assembly that contains the slot in which the adapter was plugged, use the following table to determine the part number for the field replaceable unit (FRU):

    CCIN or FFC Type and model Part number Description Location code
      9406-MMA, 9117-MMA 42R7352 I/O backplane Un-P1
      5790, 7311-D11 80P6626 I/O backplane Un-P1
      0595, 5095, 7311-D20 39J0515 I/O backplane Un-P1
      5796, 7314-G30 10N7677 I/O backplane Un-P1
      5094 39J3058 I/O backplane Un-CB1

  3. Replace the adapter if the adapter does not successfully re-configure into the new slot. This ends the procedure.
  4. If the adapter is successfully re-configured in the new slot (behind another PCI host bridge), the slot in which the adapter was originally plugged is bad, replace the I/O backplane, use the following table to determine the part number for the field replaceable unit (FRU):

    CCIN or FFC Type and model Part number Description Location code
      9406-MMA, 9117-MMA 42R7352 I/O backplane Un-P1
      5790, 7311-D11 80P6626 I/O backplane Un-P1
      0595, 5095, 7311-D20 39J0515 I/O backplane Un-P1
      5796, 7314-G30 10N7677 I/O backplane Un-P1
      5094 39J3058 I/O backplane Un-CB1

  5. Replace the adapter if the adapter does not successfully re-configure into the new slot. This ends the procedure.