PGDPART

  1. Power off the server.
  2. If the SPCN is on a card, check that the SPCN card is connected and seated properly.
  3. Check that the power supplies are connected and seated properly.
  4. Power on the server.
  5. Is there a reference code 1xxx 2600, 2601, or 2603?
    • No: This ends the procedure.
    • Yes: Exchange the following FRUs one at a time:
      • Power supplies
      • SPCN card, service processor, or I/O Backplane (as appropriate)
      • Memory cards
      • Processor cards

        Use the following tables to determine the part number for the field replaceable unit (FRU):

        9406-MMA, 9117-MMA

        CCIN or FFC Type and model Part number Description Location code
          9406-MMA, 9117-MMA 42R8010 Power supplies Un-Ex
          9406-MMA, 9117-MMA 10N8752 Service processor card (the SPCN function is built into the service processor card for this system) Un-P1-C11
          9406-MMA, 9117-MMA 42R7352 I/O Backplane Un-P1
        319B 9406-MMA, 9117-MMA 15R7433 512MB DDR2 memory card Un-P2-Cx-Cy
        319C 9406-MMA, 9117-MMA 15R7436 1GB DDR2 memory card Un-P2-Cx-Cy
        319E 9406-MMA, 9117-MMA 15R7439 2GB DDR2 memory card Un-P2-Cx-Cy
        319D 9406-MMA, 9117-MMA 15R7445 4GB DDR2 memory card Un-P2-Cx-Cy
        319F 9406-MMA, 9117-MMA 15R7448 8GB DDR2 memory card Un-P2-Cx-Cy
          9406-MMA, 9117-MMA 10N9146 3.5 GHz POWER6, 2 Core Processor Card Un-P2-Cx
          9406-MMA, 9117-MMA 10N9144 4.2 GHz POWER6, 2 Core Processor Card Un-P2-Cx
          9406-MMA, 9117-MMA 10N9139 4.7 GHz POWER6, 2 Core Processor Card Un-P2-Cx

        5790, 7311-D11

        CCIN or FFC Type and model Part number Description Location code
          5790, 7311-D11 22R3958 Power supplies Un-Ex
          5790, 7311-D11 80P6626 I/O drawer backplane Un-P1

        0595, 5095, 7311-D20

        CCIN or FFC Type and model Part number Description Location code
          0595, 5095, 7311-D20 39J2781 Power supplies Un-Ex
          0595, 5095, 7311-D20 39J0515 I/O drawer backplane Un-P1

        5796, 7314-G30

        CCIN or FFC Type and model Part number Description Location code
          5796, 7314-G30 42R4491 Power supplies Un-Ex
          5796, 7314-G30 10N8867 SPCN Card Un-P1-C8
          5796, 7314-G30 10N7677 I/O drawer backplane Un-P1