This is a primary PCI bus generated under a RIO/HSL/12X adapter I/O bridge.
This bus can be in a system unit or I/O unit, and on some units this bus connects two FRUs.
| Type and model of unit containing the failing item | Action |
| 9406-MMA, 9117-MMA | Perform SYSBKPL. |
| 5790, 7311-D11 | There are two potential failing items. Perform SIADPCD. If the problem persists after powering on the frame or unit, then perform TWRPLNR.
Attention: To prevent system VPD problems, do not replace both FRUs at the same time. |
| 0595, 5095, 7311-D20 | There are two potential failing items. Perform SIADPCD. If the problem persists after powering on the frame or unit, then perform TWRPLNR.
Attention: To prevent system VPD problems, do not replace both FRUs at the same time. |
| 5796, 7314-G30 | There are two potential failing items. Perform SIADPCD. If the problem persists after powering on the frame or unit, then perform TWRPLNR.
Attention: To prevent system VPD problems, do not replace both FRUs at the same time. |
This ends the procedure.