The multi-adapter bridge detected a problem with a card location that it controls.
The problem is in the controls for the card slot. The card location may or may not have an installed card. If there is a card installed in that location, it may be the source of the problem. In some cases, the user interface view of the servicable event will list more than one card position for this FRU's location. The problem may be with any one of the FRU's in those locations. When there is a list of locations in this FRU's location code, the card locations will be separated by commas. A range of card positions will show the starting card position, a colon, and the ending card position.
Note: Any IOPs plugged into slots owned by a Linux® partition will not power on. This error will be logged. Correct the situation by removing the IOP cards.
This ends the procedure.
Is the multi-adapter bridge function number less than or equal to 7?
This ends the procedure. This ends the procedure.
The card location
with a multi-adapter bridge function number one less than the multi-adapter
bridge function number in the DSA has a 64-bit card installed. The 64-bit
card is using the 32-bit PCI bus of the card location specified in the DSA. To
determine the multi-adapter bridge function numbers and the card locations
they specify, see DSA translation, "DSA translation" is available in the service guide for the system unit.
Problem or message
Meaning or corrective action
Slot unavailable due to 64-bit card in adjacent slot.
The card location specified in the DSA is unavailable
for the card installed there. Do not use that card location.
LED control failure, do not use slot.
System code has detected a problem with the controls
for the LED at the card location specified by the DSA. Do not use that card
location.
Power control failure, do not use slot.
System code has detected a problem with the power controls
at the card location specified by the DSA. Do not use that card location.
Multi-adapter bridge card slot error, do not use card
slot.
System code has detected a problem with the controls
at the card location specified by the DSA. Do not use that card location.
This ends the procedure.