SPNETWK
A connection between an HMC and a service processor
has been lost. The location code will identify the unit to which contact was
lost.
- Is the system receiving power?
- No: Take the necessary action to restore power to the system. This
ends the procedure.
- Yes: Continue with the next step.
- Verify the network connection
between the service processor and the HMC. See the table below for location
information.
| FRU
name (check in order, one at a time) |
Location |
| For each unit, starting
with the primary unit and then the secondary units: |
|
Service processor cable, Ethernet cable |
Un-P1-C11-T3 |
Does the problem persist?
- No: This ends the procedure.
- Yes: Continue with the next step.
- Shut down the operating system for the server in preparation to
reboot the server. Reapply the power and boot the server.
Does the problem persist?
- No: This ends the procedure.
- Yes: Continue with the next step.
- Use SVCPROC to replace the service processor. If the problem persists, contact your next level of support.