TWRPLNR

The failing component is in the PCI I/O backplane of an I/O unit.

  1. Are you working from the serviceable event view and a card location is listed with this failing item, or do you already know the unit or feature type where the failure is?
    • Yes: The listed card location is where the error is located. Continue with the next step.
    • No: Record the bus number value, BBBB, in word 7 of the reference code. Word 7 of the reference code allows you to determine the correct bus number, bus type, multi-adapter bridge number, multi-adapter bridge function number, and logical card number from the Direct Select Address (DSA), see DSA translation. "DSA translation" is also available in the service guide for the system unit. Continue with the next step.

  2. Use the following table to determine the part number for the field replaceable unit (FRU):
    CCIN or FFC Type and model Part number Description Location code
      5790, 7311-D11 80P6626 I/O backplane Un-P1
      0595, 5095, 7311-D20 39J0515 I/O backplane Un-P1
      5796, 7314-G30 10N7677 I/O backplane Un-P1
      5094 39J3058 I/O backplane Un-CB1

This ends the procedure.