UPSUNIT
The uninterruptible power supply (UPS) might be the failing component.
Perform the following:
- Is the problem that the system has a UPS reference code, but the UPS does not have a fault code?
- Yes: Continue with the next step.
- No: Go to step 3.
- Remove the UPS signal cable from the system connector. Does the system report a UPS reference code now?
- No: Continue with the next step.
- Yes: Replace the following, one at a time, until the problem is resolved, use the following table to determine the part number for the field replaceable unit (FRU):
| CCIN or FFC |
Type and model |
Part number |
Description |
Location code |
| |
9406-MMA, 9117-MMA |
10N8752 |
Service processor card (SPCN function for the system unit) |
Un-P1-C11 |
| |
UPS |
|
Remote power controller (RPC) |
|
This ends the procedure.
Perform the following: - Verify the UPS signal cable, between the UPS and the system,
is connected and seated properly.
- Have the customer call the UPS provider for service if a problem
is found.
- Call service support if the problem prevails after the UPS is
verified as working correctly.
This ends the procedure.