The system detected a voltage problem.
Perform the following to service this FRU.
- Power off the system.
- Unplug the AC.
- Reseat the VRMs. Refer to the "Locations" section of the service guide for the system unit for voltage regulator modules. Does
that resolve the problem?
- Yes: This ends the procedure.
- No: Continue with the next step.
- Replace the VRMs. Use the following table to determine the part number for the field replaceable unit (FRU):
| CCIN or FFC |
Type and model |
Part number |
Description |
Location code |
| |
9406-MMA, 9117-MMA |
42R7459 |
Voltage regulator assembly |
Un-P2-C3 |
| |
9406-MMA, 9117-MMA |
42R7459 |
Voltage regulator assembly |
Un-P2-C4 |
| |
9406-MMA, 9117-MMA |
42R7459 |
Voltage regulator assembly |
Un-P2-C5 |