This function allows you to perform a system power control network
(SPCN) operation.
This function is available only in the manual operating mode and
from power on standby.
Notes: - The system that will display the ID must be powered off with ac power
applied.
- If you have just restored power to the system, the service
processor must return to standby mode before the control panel functions will
work correctly. Returning the service processor to standby mode takes a few
minutes after the panel appears to be operational.
- The control panel must be in manual operating mode to access function
07 options.
To perform an SPCN operation that is controlled by function
07, do the following:
- Select function 07, and then press Enter. 07** is
displayed.
- Select the function that you want to perform (see Table 1). Use the Increment or Decrement
buttons (↑↓) to scroll to the appropriate function. Press Enter to display 07nn00,
where nn is the function that you selected.
Table 1. SPCN functions in function 07| Function |
Description |
For more information |
| A1 |
Broadcasts a power-on command. |
Go to step
5. |
| A6 |
Displays frame address on all I/O enclosures. |
Go to step
5. |
| A8 |
Displays the SPCN configuration ID number for a selected
frame. |
07A8 is displayed. Go to step 3. |
| A9 |
Sets the SPCN configuration ID for a selected frame. |
07A9 is displayed. Go to step 4. |
- If you selected function A8 in step 2, complete the following steps to display the configuration
of the I/O enclosure:
- Use the Increment (↑) or Decrement (↓) buttons to select the first two
characters of the frame address of the I/O enclosure, and then press Enter. 07nn00 is
displayed, where nn is the first byte
of the frame address.
- Use the Increment (↑) or Decrement (↓) buttons to select the second two
characters of the frame address of the I/O enclosure, and then press Enter. 07nn00 is
displayed on the selected I/O enclosure, where nn is
the second byte of the frame address.
Notes: - The display on the addressed I/O enclosure is blinking on and off.
- The configuration ID is the last two characters of the bottom line.
- If you selected function A9 in step 2, complete the following steps to set the configuration
of the selected I/O enclosure:
- Ensure that the system power of the selected I/O enclosure is in standby
mode. If the system power of the selected I/O enclosure is not in standby
mode, power it off. Then return to step
1.
- Use the (↑) or Decrement (↓) buttons to select the first two characters
of the frame address of the I/O enclosure to configure, and then press Enter. 07nn00 is
displayed, where nn is the first byte of the unit
address.
- Use the Increment (↑) or Decrement (↓) buttons to select the second two
characters of the frame address of the I/O enclosure, and then press Enter. 07nn00 is
displayed, where nn is the second byte of the frame
address.
Note: The display on the addressed I/O enclosure is blinking on and
off.
- Use the Increment (↑) or Decrement (↓) buttons to select the correct configuration
ID. 07nn is displayed, where nn is
the configuration ID.
- Press Enter. 07nn00 is displayed. After 20 to
30 seconds, the display on the addressed I/O enclosure stops blinking and
returns to the normal display format.
- Scroll to 07** using the Increment
(↑) or Decrement (↓) buttons, and then press Enter. This returns the control
panel to the normal display.