Resequence the SPCN addressing to ensure that minimal sequencing
changes occur during the conversion. Learn how to resequence the SPCN
addressing.
Before generating any printouts, resequence the system
power control network (SPCN) addressing. This ensures that when the
authorized service provider performs the SPCN address resequencing
after the expansion unit conversion, minimal sequencing changes occur.
To resequence the SPCN addressing, complete the following steps:
- At an IBM® i command line, enter STRSST to start system
service tools (SST) and sign on to SST.
Note: To use SST,
you need a valid service tools user ID. See the service tools user
ID topic for more information.
- From the SST main menu, select option 5 (Work with system
partitions), and then press Enter. The Work with System Partitions
display is shown.
- Select option 2 (Work with partition status). The Work
with Partition Status display is shown.
- Type 10 next to the Partition, and then press
Enter to place the logical partition in manual mode.
- From the Work with Partition Status display, type 33 next to the partition, and press Enter to resequence the SPCN addressing.
Result: The status message Reorder SPCN addressing was
successful appears.