Resequencing SPCN addressing

Resequence the SPCN addressing to ensure that minimal sequencing changes occur during the conversion. Learn how to resequence the SPCN addressing.

Before generating any printouts, resequence the system power control network (SPCN) addressing. This ensures that when the authorized service provider performs the SPCN address resequencing after the expansion unit conversion, minimal sequencing changes occur.

To resequence the SPCN addressing, complete the following steps:

  1. At an IBM® i command line, enter STRSST to start system service tools (SST) and sign on to SST.
    Note: To use SST, you need a valid service tools user ID. See the service tools user ID topic for more information.
  2. From the SST main menu, select option 5 (Work with system partitions), and then press Enter. The Work with System Partitions display is shown.
  3. Select option 2 (Work with partition status). The Work with Partition Status display is shown.
  4. Type 10 next to the Partition, and then press Enter to place the logical partition in manual mode.
  5. From the Work with Partition Status display, type 33 next to the partition, and press Enter to resequence the SPCN addressing.
Result: The status message Reorder SPCN addressing was successful appears.