Use this procedure to exchange the I/O processor (IOP) for the
system or partition console of i5/OS®.
- Is the system managed by an HMC?
- No: Go to step 6.
- Yes: The HMC will be required for this procedure.
Move to the HMC and continue with the next step only if the HMC is functional.
- Can the customer power off the partition at this time?
- Yes: Power off the partition from the operating
system console or the HMC. Then, continue with the next step.
- No: The IOP controlling the partition's console
may be controlling other critical resources. The partition must be powered
off to exchange this IOP. Perform this procedure when the customer is able
to power off the partition. Then, continue with the next step.
- Perform the following to determine the unit machine type, model,
and serial number where the console IOP is located and the location of the
console IOP:
- From the Navigation Area of the HMC, select the Management
Environment.
- Select and expand the HMC environment for this HMC.
- Select and expand Server and Partition.
- Select Server Management.
- Double-click the i5/OS partition you are working on.
- Select the Settings tab.
- Record the location of the load source IOP. The unit
type, model, and serial number are the first three parts of the location code
and are separated by periods.
- Continue with the next step.
- Record the frame type or feature by using the frame ID and system
configuration listing or by locating the frame with that ID and recording
the frame type or feature.
- Perform the following to exchange the IOP in that card position:
- Go to System FRU locations and select the
unit type and model that you recorded.
- Locate the card position in the FRU locations table and use
the exchange procedure that is identified.
- Power on the partition.
This ends the
procedure.
- The problem is in the i5/OS partition of a system with one or
more partitions that is not managed by an HMC. Use the table below
to determine the location of the load source IOP and the appropriate exchange
procedure.
| Model |
Load source IOP location |
Load source IOA location |
Link to locations information |
| MMA |
-P1-C1 |
embedded SCSI in -P1 |
System FRU locations |
This ends the procedure.