Use this procedure to determine the reference code, which
is used to isolate a problem and to determine the failing device.
- If the system has logical partitions, perform this procedure
from the logical partition that reported the problem. To
determine if the system has logical partitions, go to determining
if the system has logical partitions.
- Look in the Service action log for other errors logged
at or around the same time as the 310x SRC. If no entries
appear in the service action log, use the product activity log .
Use the other SRCs to correct the problem before performing an IPL.
Contact your next level of support as necessary for assistance with
SCSI bus problem isolation. If the problem is not corrected, continue
with the next step.
- Perform an IPL to dedicated service tool (DST). See dedicated
service tools.
Does
an SRC appear on the control panel?
- Yes: Go to step 6.
- No: Does either the Disk Configuration
Error Report, the Disk Configuration Attention Report, or the Disk
Configuration Warning Report display appear?
- Yes: Continue with the next step.
- No: Go to step 5.
- Does one of the following messages appear in the list?
- Missing disk units in the configuration
- Missing mirror protection disk units in the configuration
- Device parity protected units in exposed mode
- No: Continue with the next step.
- Yes: Select option 5,
press F11, and then press Enter to
display the details.
If any of the reference codes
are not 0000, go to step 6 and
use the reference code that is not 0000.
Note: Use the characters
in the Type column to find the correct reference code table.
- Does the Display Failing System Bus display
appear?
- Record the SRC.
Is the SRC
the same one that sent you to this procedure?
- Yes: Continue with the next step.
- No: Perform problem analysis to correct
the problem. This ends the procedure.
- Perform the following:
- Power off the system or expansion tower.
- See using failing item codesto
find the devices identified by FI code FI01106.
- Disconnect one of the disk units, (other than the load-source
disk unit), the tape units, or the optical storage units that are
identified by FI code FI01106. Slide it partially out of the system.
Note: Do not disconnect the load-source disk unit, although
FI code FI01106 may identify it.
- Power on the system or the expansion tower that you powered
off.
Does an SRC appear on the control panel?
- No: Continue with the next step.
- Yes: Go to step 12.
- Does either the Disk Configuration Error Report, the Disk
Configuration Attention Report, or the Disk Configuration Warning
Report display appear with one of the following listed?
- Missing disk units in the configuration
- Missing mirror protection disk units in the configuration
- Device parity protected units in exposed mode
- Yes: Continue with the next step.
- No: Go to step 11.
- Select option 5, press F11,
and then press Enter to display details.
Does an SRC appear in the Reference Code column?
- No: Continue with the next step.
- Yes: Go to step 12.
- Look at all the Product activity logs by
selecting Product activity log under DST.
Is an SRC logged as a result of this IPL?
- Yes: Continue with the next step.
- No: The last device you disconnected is
the failing item. Exchange the failing device and reconnect the devices
that were disconnected previously.
This
ends the procedure.
- Record the SRC.
Is the SRC
the same one that sent you to this procedure?
- No: Continue with the next step.
- Yes: The last device you disconnected is
not the failing item.
- Leave the device disconnected and go to step 7 to continue isolation.
- If you have disconnected all devices that are identified by FI
code FI01106 except the load-source disk unit, reconnect all devices.
Then, go to step 15.
- Does the Disk Configuration Error Report, the Disk Configuration
Attention Report, or the Disk Configuration Warning Report display
appear with one of the following listed?
- Missing disk units in the configuration
- Missing mirror protection disk units in the configuration
- Device parity protected units in exposed mode
- Yes: Continue with the next step.
- No: Use the reference code to correct
the problem. This ends the procedure.
- Select option 5, press F11,
and then press Enter to display details.
Are all the reference codes 0000?
- No: Use the reference code to correct the
problem. This ends the procedure.
- Yes: The last device you disconnected is
the failing item.
- Reconnect all devices except the failing item.
- Before exchanging a disk unit, go to using
location codes. This
ends the procedure.
- Was disk unit 1 (the load-source disk unit)
a failing item that FI code FI01106 identified?
- Yes: The failing items that FI code FI01106
identified are not failing. The load-source disk unit may be failing.
Use the original SRC and exchange the failing items, starting with
the highest probable cause of failure. If the failing item list contains
FI codes, see using failing item codes to
help determine part numbers and location in the system. This
ends the procedure.
- No: The failing items that FI code FI01106
identified are not failing. Use the original SRC and exchange the
failing items, starting with the highest probable cause of failure.
If the failing item list contains FI codes, see using
failing item codesto
help determine part numbers and location in the system. This
ends the procedure.