A status indication for a RIO/HSL loop is identified in the reference code.
Use the table below to determine if the status indication requires a service action. Record the rightmost four characters of word 4 of the reference code. These characters are the program return code (PRC), which indicates the RIO/HSL status. The leftmost four characters of word 7 indicate the RIO/HSL loop number (in hexadecimal format).
| PRC | Indicated status |
|---|---|
| 3204 | A RIO error was detected, indicating that a RIO link
failed.
|
| 3205 | During IPL, LIC determined that the loop was not complete.
|
| 3206 | During normal operation an RIO/HSL loop recovered its redundant path. The loop is now complete. |
| 3208 | During normal operation an RIO/HSL I/O bridge recovered a failed link on the loop. |
| 3209 | See Indicated status for PRC 3209 below. |
| 3210 | An RIO/HSL link
switched to a slower speed. The link is designed to run at a faster speed
based on the link's hardware and LIC levels at both ends. If there is a FRU
list in the serviceable event view, use it to complete the repair action.
If not, perform the following sections of this procedure below:
|
Recoverable CRC (cyclical redundancy check) errors have occurred on the loop. This error requires service action. An RIO/HSL cable or connection must be exchanged. Exchange only the cable that appears in the FRU list of this reference code in this document. If you are working from the serviceable event view, then only the FRU(s) required for this error will be displayed.
Choose from the following scenarios:
This ends the procedure.
This ends the procedure.
Retrieve and record the following information:
Use the frame ID and port number indicator in the following table to determine the RIO/HSL port label. If you are referred to Converting the loop number to RIO/HSL/12X port location labels, the failing item is in a system unit. You will need the RIO/HSL loop number to determine the FRU.
The following tables provide hub, port, and location code information for each of the currently supported models. This data is used to determine which RIO loop to use for the B7006981. The asterisk in the "Port indicator number" column indicates the leading port of the port pair.
| Model number | Loop number | Hub | Port indicator number | Location code |
|---|---|---|---|---|
| 8203-E4A, 9407-M15, and 9408-M25 | 1668 | 0 | 0* | "Internal" |
| 1 | "Internal" | |||
| 1669 | 2* | P1-T4 | ||
| 3 | P1-T3 | |||
| 8204–E8A and 9409-M50 | 1668 | 0 | 0* | "Internal" |
| 1 | "Internal" | |||
| 1669 | 2* | P1-T12 | ||
| 3 | P1-T11 | |||
| 1676 | 4 | 0 | P1-C6-T2 (In an expansion card not-onboard) | |
| 1 | P1-C6-T1 (In an expansion card not-onboard) |
| Model number | Loop number | CEC | Hub | Port indicator number | Location code |
|---|---|---|---|---|---|
| 9117-MMA, and 9406-MMA | 1668 | 0 | 0 | 0* | "Internal" (Top CEC) |
| 1 | "Internal" | ||||
| 1669 | 0 | 0 | 2* | P1-T8 | |
| 3 | P1-T9 | ||||
| 1676 | 0 | 4 | 0* | P1-C7-T2 | |
| 1 | P1-C7-T1 | ||||
| 9117-MMA, and 9406-MMA | 1684 | 1 | 8 | 0* | "Internal" (Second down) |
| 1 | "Internal" | ||||
| 1685 | 1 | 8 | 2* | P1-T8 | |
| 3 | P1-T9 | ||||
| 1692 | 1 | 12 | 0 | P1-C7-T2 | |
| 1 | P1-C7-T1 | ||||
| 9117-MMA, and 9406-MMA | 1700 | 2 | 16 | 0* | "Internal" (Third down) |
| 1 | "Internal" | ||||
| 1701 | 2 | 16 | 2* | P1-T8 | |
| 3 | P1-T9 | ||||
| 1708 | 2 | 20 | 0 | P1-C7-T2 | |
| 1 | P1-C7-T1 | ||||
| 9117-MMA, and 9406-MMA | 1716 | 3 | 24 | 0* | "Internal" (Fourth down) |
| 1 | "Internal" | ||||
| 1717 | 3 | 24 | 2* | P1-T8 | |
| 3 | P1-T9 | ||||
| 1724 | 3 | 28 | 0 | P1-C7-T2 | |
| 1 | P1-C7-T1 |
| Model number | Loop number | Hub | Port indicator number | Location code |
|---|---|---|---|---|
| 9125-F2A | 1668 | 0 | 0* | "Internal" |
| 1 | "Internal" | |||
| 1669 | 2* | P1-T7 | ||
| 3 | P1-T8 |
| Model number | Loop number | Hub | Port indicator number | Location code |
|---|---|---|---|---|
| 9119-FHA | 1668 | 0 | 0* | "Internal" FSPA |
| 1 | "Internal" | |||
| 1669 | 0 | 2* | P1-C1-T1 | |
| 3 | P1-C1-T2 | |||
| 1670 | 1 | 0* | "Internal" FSPB | |
| 1 | "Internal" | |||
| 1671 | 1 | 2* | P1-C3-T1 | |
| 3 | P1-C3-T2 | |||
| 1672 | 2 | 2* | P1-C5-T1 | |
| 3 | P1-C5-T2 | |||
| 1674 | 3 | 2* | P1-C6-T1 | |
| 3 | P1-C6-T2 | |||
| 1676 | 4 | 2* | P1-C8-T1 | |
| 3 | P1-C8-T2 | |||
| 1678 | 5 | 2* | P1-C9-T1 | |
| 3 | P1-C9-T2 | |||
| 1680 | 6 | 2* | P1-C11-T1 | |
| 3 | P1-C11-T2 | |||
| 1682 | 7 | 2* | P1-C13-T1 | |
| 3 | P1-C13-T2 | |||
| 9119-FHA | 1684 | 8 | 0* | "Internal" FSB (Second node position) |
| 1 | "Internal" | |||
| 1685 | 8 | 2* | P1-C1-T1 | |
| 3 | P1-C1-T2 | |||
| 1686 | 9 | 0* | "Internal" FSPA | |
| 1 | "Internal" | |||
| 1687 | 9 | 2* | P2-C3-T1 | |
| 3 | P2-C3-T1 | |||
| 1688 | 10 | 2* | P2-C5-T1 (Optional card, no HSL) | |
| 3 | P2-C5-T2 | |||
| 1690 | 11 | 2* | P2-C6-T1 (Required empty airflow) | |
| 3 | P2-C6-T2 | |||
| 1692 | 12 | 2* | P2-C8-T1 | |
| 3 | P2-C8-T2 | |||
| 1694 | 13 | 2* | P2-C9-T1 | |
| 3 | P2-C9-T2 | |||
| 1696 | 14 | 2* | P2-C11-T1 | |
| 3 | P2-C11-T2 | |||
| 1698 | 15 | 2* | P2-C13-T1 | |
| 3 | P2-C13-T2 | |||
| 9119-FHA | 1700 | 16 | 2* | P3-C1-T1 (Third position) |
| 3 | P3-C1-T2 | |||
| 1702 | 17 | 2* | P3-C3-T1 | |
| 3 | P3-C3-T2 | |||
| 1704 | 18 | 2* | P3-C5-T1 | |
| 3 | P3-C5-T2 | |||
| 1706 | 19 | 2* | P3-C6-T1 | |
| 3 | P3-C6-T2 | |||
| 1708 | 20 | 2* | P3-C8-T1 | |
| 3 | P3-C8-T2 | |||
| 1710 | 21 | 2* | P3-C9-T1 | |
| 3 | P3-C9-T2 | |||
| 1712 | 22 | 2* | P3-C11-T1 | |
| 3 | P3-C11-T2 | |||
| 1714 | 23 | 2* | P3-C13-T2 | |
| 3 | P3-C13-T2 | |||
| 9119-FHA | 1716 | 24 | 2* | P4-C1-T1 |
| 3 | P4-C1-T2 | |||
| 1718 | 25 | 2* | P4-C3-T1 | |
| 3 | P4-C3-T2 | |||
| 1720 | 26 | 2* | P4-C5-T1 | |
| 3 | P4-C5-T2 | |||
| 1722 | 27 | 2* | P4-C6-T1 | |
| 3 | P4-C6-T2 | |||
| 1724 | 28 | 2* | P4-C8-T1 | |
| 3 | P4-C8-T2 | |||
| 1726 | 29 | 2* | P4-C9-T1 | |
| 3 | P4-C9-T2 | |||
| 1728 | 30 | 2* | P4-C131-T1 | |
| 3 | P4-C11-T2 | |||
| 1730 | 31 | 2* | P4-C13-T1 | |
| 3 | P4-C13-T2 |
If there is a cable attached to the failing port:
Use the following table to determine the end point FRUs on the "From Frame ID" port. Replace the FRUs one at a time.
If replacing the end point FRUs for the "From Frame ID" port does not resolve the error, use the table below to replace the end point FRUs at the other end of the cable. Perform RIOIP08 to determine the system or I/O unit frame ID and RIO/HSL port label of the other end of the cable (if you do not already know).
| Model | Loop number (hexadecimal / decimal) | End point FRUs |
|---|---|---|
| 8203-E4A, 9407-M15, 9408-M25, 9117-MMA and 9406-MMA | 0680 / 1664 | The loop is embedded in the system unit planar. Exchange the system unit planar. |
| 8203-E4A, 9407-M15, 9408-M25, 9117-MMA and 9406-MMA | 0681 / 1665 | For all port number values, the loop's NIC/RIO controller is embedded in the system unit planar. Exchange the system unit planar. |
| 9117-MMA and 9406-MMA | 0682 / 1666 | For all port number values, the loop's NIC/RIO controller is in the NIC/RIO controller card. Exchange the NIC/RIO controller. |
| 9117-MMA and 9406-MMA | 0683 / 16670686 / 16700689 / 1673 | The loop is embedded in the system unit planar. Exchange
the system unit planar. Note: Exchange the FRU on the correct unit (primary
or secondary) by matching the serial number (if available in the FRU list
on the serviceable event view) or by matching the loop number to the correct
unit using Converting the loop number to RIO/HSL/12X port location labels.
|
This ends the procedure.