The part indicated in the FRU list that follows this procedure
is not valid or missing for this system's configuration.
Refer to
System FRU locations for information
on FRU locations called out by the following procedure.
Perform the following
to correct the problem:
- Does word 8 (the 8 leftmost characters in the 2nd line of function
13) of the reference code end with 02 or 04?
- No: Go to step 3.
- Yes: Continue with the next step.
- The FRU that is called out after this procedure is either missing
or not valid. Is that FRU installed and connected or plugged in
correctly?
- Yes: The installed FRU is not valid. Remove that
FRU. Then contact your next level of support to determine the correct FRU. This
ends the procedure.
- No: The FRU is missing. If the FRU is present
but not connected, reconnect it and perform a slow boot. See Performing
a slow boot . Otherwise,
contact your next level of support to determine the missing FRU. This
ends the procedure.
- Does word 8 end with 01 or 05?
- No: Return to the Start of Call . This ends
the procedure.
- Yes: The FRU that is listed after this procedure
has the same serial number as another FRU in the system. Remove all but one
of the FRUs that are listed after this procedure and then perform a slow boot.
See Performing a slow boot . This
ends the procedure.