FSPSP12

The DIMM FRU that was previously replaced did not correct the memory error.

Perform the following:
  1. Power off the system. See Powering on and powering off the system .
  2. To determine the action to perform, use the following table:
    System Action
    8203-E4A, 9407-M15, and 9408-M25 Replace the system backplane (Un-P1). SeeSystem FRU locations for information on system FRU locations.
    8204-E8A and 9409-M50 Replace the processor card that the DIMM is plugged into (Un-P1-C13 for processor card 1 through Un-P1-C16 for processor card 4). SeeSystem FRU locations for information on system FRU locations.
    8234-EMA, 9117-MMA, 9406-MMA , and 9125-F2A Replace the board DIMM is plugged into. SeeSystem FRU locations for information on system FRU locations.
    9119-FHA Replace the processor book with the failure.
  3. Perform a slow boot. See Performing a slow boot .

This ends the procedure.