The server has detected an over-temperature thermal fault.
- Before replacing any server hardware FRU callouts, look in the
error log for thermal problems related to fans, power supplies, etc. Perform all service actions for the thermal problem SRCs first before
continuing with any other callouts in the current SRC. Thermal problems are
associated with 1100 xxxx SRCs, where xxxx may be any of the following:
- 1514
- 1524
- 7201
- 7203
- 7205
- 7610
- 7611
- 7620
- 7621
- 7630
- 7631
- 7640
- 7641
- If no thermal-related SRCs or problems can be found, replace the
server hardware FRU called out in the current SRC. See System FRU
locations for instructions. This
ends the procedure.