An attention line has been detected as having a problem. If the
FRU replaced before this procedure did not correct the problem, perform the
following:
Refer to
System FRU locations to locate the
correct system location of the part you are replacing.
To perform the correct
FSPSP27 for the system that you are servicing, select your machine type and
model (system) from among the following:
8203-E4A,
9407-M15, and 9408-M25- Was the FRU called out before this procedure a memory DIMM (Un-P1-C14
through Un-P1-C17 or Un-P1-C21 through Un-P1-C24) or a GX adapter card (Un-P1-C8
or Un-P1-C6)?
- No:
- This ends the procedure.
- Yes:
- Continue with the next step.
- Perform the following:
- Replace the system backplane (Un-P1).
- Perform a slow boot. See Performing a slow boot . This ends
the procedure.
8204-E8A and 9409-M50- Was the FRU called out before this procedure a Memory DIMM (Un-P1-C13-Cx
or Un-P1-C14-Cx or Un-P1-C15-Cx or Un-P1-C16-Cx)?
- No:
- Go to step 4.
- Yes:
- Continue with the next step.
- Perform the following:
- Replace the processor card (Un-P1-C13 or Un-P1-C14 or Un-P1-C15 or Un-P1-C16)
that the DIMM was plugged into.
- Perform a slow boot
Does the problem persist?
- No:
- This ends the procedure.
- Yes:
- Continue with the next step.
- Perform the following:
- Replace the system backplane (Un-P1).
- Perform a slow boot. See Performing a slow boot .
- Was the FRU called out before this procedure a processor
card (Un-P1-C13 or Un-P1-C14 or Un-P1-C15 or Un-P1-C16) or GX adapter card
(Un-P1-C8 or Un-C1-C7)?
- No:
- This ends the procedure.
- Yes:
- Continue with the next step.
- Perform the following:
- Replace the system backplane (Un-P1).
- Perform a slow boot. See Performing a slow boot . This ends
the procedure.
8234-EMA, 9117-MMA, and 9406-MMA- 1. Was the FRU called out before this procedure a memory DIMM (Un-P2-C1-Cx
or Un-P2-C2-Cx)?
- No:
- Go to step 10 .
- Yes:
- A memory DIMM attention line has an error. Continue to the next step.
- Replace the service processor (Un-P1-C11) from the same drawer as the
memory DIMM.
- Perform a slow boot. See Performing a slow boot .
- Does the problem persist?
- No:
- This ends the procedure.
- Yes:
- Continue to the next step.
- Replace the processor card (Un-P2-C1 or Un-P2-C2) on which you previously
replaced DIMMs.
- Perform a slow boot.
- Does the problem persist?
- No:
- This ends the procedure.
- Yes:
- Continue with the next step.
- Replace the system backplane (Un-P1) from the same drawer as the memory
DIMM.
- Perform a slow boot.
- Was the FRU called out before this procedure a processor
card (Un-P2-C1 or Un-P2-C2) or GX adapter card (Un-P1-C8 or Un-P1-C9)?
- No:
- Go to step 16.
- Yes:
- A processor card or GX adapter card attention line has an error. Continue
to the next step.
- Replace the service processor (Un-P1-C11) from the same drawer as the
processor card or GX adapter card.
- Perform a slow boot.
- Does the problem persist?
- No:
- This ends the procedure.
- Yes:
- Continue with the next step.
- Replace the system backplane (Un-P1) from the same drawer as the processor
card or GX adapter card.
- Perform a slow boot. Performing a slow boot . This ends
the procedure.
- Was the FRU called out before this the system backplane
(Un-P1)?
- No:
- Contact your next level of support. This ends the procedure.
- Yes:
- A P5IOC2 attention line has an error. Continue to the next step.
- Replace the service processor (Un-P1-C11) from the same drawer as the
system backplane.
- Perform a slow boot. This ends the procedure.
9125-F2A- Was the FRU called out before this procedure a memory DIMM (Un-P2-Cx,
where x = 1 - 64) or GX adapter card (Un-P2-C65 or Un-P2-C66)?
- No:
- Go to step 7.
- Yes:
- Continue to the next step.
- Replace the I/O backplane (Un-P1).
- Perform a slow boot. See Performing a slow boot .
- Does the problem persist?
- No:
- This ends the procedure.
- Yes:
- Continue to the next step.
- Replace the processor backplane (Un-P2).
- Perform a slow boot.
- Was the FRU called out before this procedure a processor
(Un-P2-Cx, where x = 67 - 82) or processor backplane (Un-P2)?
- No:
- This ends the procedure.
- Yes:
- Continue with the next step.
- Replace the I/O backplane (Un-P1).
- Perform a slow boot. This ends the procedure.
9119-FHA- Was the FRU called out before this procedure a memory DIMM (Un-Pm-Cx,
where m = 2 - 9 and x = 1 - 36), a processor (Un-Pm-Cx, where m = 2 - 9 and
x = 25 - 28), or GX adapter card (Un-Pm-Cx, where m = 2 - 9 and x = 37 - 40)?
- No:
- This ends the procedure.
- Yes:
- A Memory DIMM or Processor or GX Adapter Card attention line has an error.
Continue to the next step.
- Replace both Node FSP Cards (Un-Pm-C41 and Un-Pm-C42, where m = 2 - 9)
from the same node as the memory DIMM, processor, or GX adapter card.
- Perform a slow boot.
- Does the problem persist?
- No:
- This ends the procedure.
- Yes:
- Continue to the next step.
- Replace the processor book (Un-Pm, where m = 2 - 9) the memory DIMM, processor,
or GX adapter card plugged into.
- Perform a slow boot. This ends the procedure.