FSPSP32

A problem with the enclosure has been found.

The problem is resulting from one of the following:

Refer to System FRU locations for instructions for removing and replacing any FRUs called out by the following procedure.

Perform the following:

  1. Record the reason code (the last 4 characters of word 11) from the SRC by looking at the operator panel or accessing the error log with the ASMI.
  2. Is the reason code A46F?
    • No: Go to step 5.
    • Yes: Continue with the next step.
  3. Check for and apply any server firmware updates. Does the problem persist?
    • No: This ends the procedure.
    • Yes: Continue with the next step.
  4. Use the following table to determine the action to perform.
    System Action
    8203-E4A, 9407-M15, 9408-M25, 8204-E8A and 9409-M50 Perform the following:
    1. Power off the system. See Powering on and powering off the system .
    2. Replace the system backplane (Un-P1).
    3. Perform a slow boot. See Performing a slow boot .

      Does the problem persist?

      No:
      This ends the procedure.
      Yes:
      Contact your next level of support. This ends the procedure.
    8234-EMA, 9117-MMA, and 9406-MMA Perform the following:
    1. Power off the system. See Powering on and powering off the system .
    2. Replace the service processor.
    3. Perform a slow boot. See Performing a slow boot .
      Does the problem persist?
      No:
      This ends the procedure.
      Yes:
      Continue with the next step.
    4. Power off the system (see “Powering on and powering off” on page 608).
    5. Replace the system backplane.
    6. Perform a slow boot.

      Does the problem persist?

      No:
      This ends the procedure.
      Yes:
      Contact your next level of support. This ends the procedure.
    9125-F2A Perform the following:
    1. Power off the system. See Powering on and powering off the system .
    2. Replace the I/O Backplane (Un-P1).
    3. Perform a slow boot. See Performing a slow boot
      Does the problem persist?
      No:
      This ends the procedure.
      Yes:
      Contact your next level of support. This ends the procedure.
    IBM® Power 595 (9119-FHA) Perform the following:
    1. Power off the system. See Powering on and powering off the system .
    2. Replace both CEC service processor cards.
    3. Perform a slow boot. See Performing a slow boot .

      Does the problem persist?

      No:
      This ends the procedure.
      Yes:
      Continue with the next step.
    4. Power off the system. See Powering on and powering off the system ..
    5. Replace the CEC Midplane (Un-P1).
    6. Perform a slow boot. See Performing a slow boot .

      Does the problem persist?

      No:
      This ends the procedure.
      Yes:
      Contact your next level of support. This ends the procedure.
  5. Is the reason code A460?
    • No: Go to step 7.
    • Yes: Continue with the next step.
  6. Perform the following:
    1. Set the enclosure serial number using the ASMI. See Setting the system identifyers .
    2. The service processor will automatically reset when leaving the ASMI after updating the serial number.
    3. Perform a slow boot. See Performing a slow boot .

    Does the problem persist?

    • No: This ends the procedure.
    • Yes: Contact your next level of support. This ends the procedure.
  7. Is the reason code A45F?
    • No: Contact your next level of support. This ends the procedure.
    • Yes: Continue with the next step.
  8. Perform the following:
    1. Set the enclosure feature code using the ASMI. See Setting the system enclosure type . The service processor will automatically reset when leaving the ASMI after updating the serial number.
    2. Perform a slow boot. See Performing a slow boot .

    Does the problem persist?

    • No: This ends the procedure.
    • Yes: Contact your next level of support. This ends the procedure.