The system has detected an error within the JTAG path.
Replace all FRUs explicitly called out, if any, in the service processor
error log entry first before continuing in this procedure. Skip those FRUs
that have already been replaced during this service call. If one or more of
those FRUs fixes the problem,
this ends the procedure.
Note: In the
"Priority" field in the FRU list, "replace these as a group" may appear even
though only one FRU is listed. If that is the case, "replace as a group"
can be ignored.
Refer to System FRU locations for information
on locating FRUs called out by this procedure.
If the FRU(s) that have
been replaced so far have not corrected the problem, perform the following:
Select
the system that you are servicing and then perform the indicated FSPSP29 procedure.
8203-E4A, 9407-M15, and 9408-M25
8204-E8A and 9409-M50
8234-EMA, 9117-MMA, and 9406-MMA
9125-F2A
9119-FHA
8203-E4A,
9407-M15, and 9408-M25
- Was the FRU called out before this procedure a memory DIMM (Un-P1-C14
through Un-P1-C17 or Un-P1-C21 through Un-P1-C24) or a GX adapter card (Un-P1-C8
or Un-P1-C6)?
- No:
- This ends the procedure
- Yes:
- Continue with 2.
- Replace the system backplane (Un-P1).
- Perform a slow boot. To review the "Performing a slow boot" procedure
go to Performing a slow boot . This ends
the procedure.
8204–E8A and 9409-M50- Was the FRU called out before this procedure a memory DIMM (Un-P1-C13-Cx
or Un-P1-C14-Cx or Un-P1-C15-Cx or Un-P1-C16-Cx)?
- No:
- Go to step 4.
- Yes:
- Continue with the next step.
- Perform the following:
- Replace the processor card (Un-P1-C13 or Un-P1-C14 or Un-P1-C15 or Un-P1-C16)
that the DIMM was plugged to.
- Perform a slow boot. See Performing a slow boot .
- Does the problem persist?
- No:
- This ends the procedure
- Yes:
- Continue with the next step.
- Perform the following:
- Replace the system backplane (Un-P1).
- Perform a slow boot. To review the "Performing a slow boot" procedure
go to Performing a slow boot . This ends
the procedure.
- Was the FRU called out before this procedure a processor
card (Un-P1-C13 or Un-P1-C14 or Un-P1-C15 or Un-P1-C16) or GX adapter card
(Un-P1-C8 or Un-C1-C7)?
- No:
- This ends the procedure.
- Yes:
- Continue with the next step.
- Perform the following:
- Replace the system backplane (Un-P1).
- Perform a slow boot. See Performing a slow boot . This ends
the procedure.
8234-EMA, 9117-MMA, and 9406-MMA- Has a Memory DIMM (Un-P2-C1-Cx or Un-P2-C2-Cx) been replaced?
- No:
- Go to step 10.
- Yes:
- A Memory DIMM attention line has an error. Continue to the next step.
- Replace the service processor (Un-P1-C11) in the same drawer as the Memory
DIMM.
- Perform a slow boot. To review the "Performing a slow boot" procedure
go to Performing a slow boot .
- Does the problem persist?
- No:
- This ends the procedure.
- Yes:
- Continue to the next step.
- Replace the processor card (Un-P2-C1 or Un-P2-C2) on which a DIMM has
been replaced.
- Perform a slow boot. See Performing a slow boot .
- Does the problem persist?
- No:
- This ends the procedure.
- Yes:
- Continue with the next step.
- Replace the system backplane (Un-P1) in the same drawer as the Memory
DIMM.
- Perform a slow boot. See Performing a slow boot . This ends
the procedure.
- Has a processor card (Un-P2-C1 or Un-P2-C2) or GX adapter
card (Un-P1-C8 or Un-P1-C9) been replaced?
- No:
- Go to step 16
- Yes:
- A processor card or GX adapter card attention line has an error. Continue
to the next step.
- Replace the service processor (Un-P1-C11) from the same drawer as the
processor card or GX adapter card.
- Perform a slow boot. See Performing a slow boot .
- Does the problem persist?
- No:
- This ends the procedure.
- Yes:
- Continue with the next step.
- Replace the system backplane (Un-P1) from the same drawer as the processor
card or GX adapter card.
- Perform a slow boot. This ends the procedure.
- Was the system backplane (Un-P1) explicitly called out
as a FRU before starting step 1 of this procedure?
- No:
- Contact your next level of support. This ends the procedure.
- Yes:
- A P5IOC2 attention line has an error. Continue to the next step.
- Replace the service processor (Un-P1-C11) from the same drawer as the
system backplane.
- Perform a slow boot. See Performing a slow boot . This ends
the procedure.
9125-F2A- Was the FRU called out before this procedure a GX adapter card (Un-Pm-Cx,
where m = 2 - 9 and x = 37 - 40)?
- No:
- This ends the procedure.
- Yes:
- Continue to the next step.
- Replace both node FSP cards (Un-Pm-C41 and Un-Pm-C42, where m = 2 - 9)
from the same Node as the GX adapter card.
- Perform a slow boot. To review the "Performing a slow boot" procedure
go to Performing a slow boot .
- Does the problem persist?
- No:
- This ends the procedure.
- Yes:
- Continue to the next step.
- Replace the processor book (Un-Pm, where m = 2 - 9) the GX adapter card
plugged into.
- Perform a slow boot. See Performing a slow boot .This ends
the procedure.
9119-FHA
This procedure is not applicable
to the 9119–FHA