An error communicating between two system processors was detected.
Refer to System FRU locations for instructions
on locating FRUs found on your system.
There is a communication error
between the processors and the FRUs called out before this procedure. If you
were unable to correct the problem by replacing FRUs that were previously
specified before coming to this procedure, consider the possibility of failing
system backplanes.
If you are servicing a 8234-EMA, 9117-MMA, and 9406-MMA,
go to 8234-EMA, 9117-MMA, and
9406-MMA
All systems except 8234-EMA, 9117-MMA,
and 9406-MMA
8234-EMA, 9117-MMA, and 9406-MMA- Use the location codes for the FRUs that were previously
specified to determine if the system processors are on separate nodes. Are
the system processors on separate nodes?
- No:
- Continue with step 2.
- Yes:
- Do the following:
- Power off the system. See Powering on and powering off the system.
- Replace the SMP cables between the two enclosures.
- Perform a slow boot. See Performing a slow boot.
- Is the problem resolved?
- Yes:
- This ends the procedure.
- No:
- Continue with the next step.
- Power off the system. See Powering on and powering off the system
- Replace the bad node backplane.
- Perform a slow boot. See Performing a slow boot. This ends the
procedure.