FSPSP46

Some corrupt areas of flash or RAM have been detected on the service processor.

  1. Use the following table to determine the action to perform.
    System Action
    8203-E4A, 9407-M15, 9408-M25, 8204-E8A, 9409-M50 Replace the system backplane (Un-P1). See System FRU locations for information on system FRU location.
    8234-EMA, 9117-MMA, and 9406-MMA Replace the Service Processor.
    1. If the last byte in word 3 of the SRC is a 10, replace the primary unit, service processor (Un-P1-C11).
    2. If the last byte in word 3 of the SRC is a 20, replace the scondary unit 1, service processor (Un-P1-C11).
    9125-F2A Replace the I/O backplane (Un-P1).
    9119-FHA Replace the failing CEC service processor card.
  2. Perform a slow boot. See Performing a slow boot .

This ends the procedure.