An error has been detected on a bus between two FRUs. The endpoint
FRUs have been called out. However, the source of the error could be the bus
path between the FRUs.
Refer to
System FRU locations for information
on FRU and removal when performing FSPSP55.
8203-E4A,
9407-M15, 9408-M25, 8204-E8A, and 9409-M50
Perform the following
task:
- Is word 6 (the 8 leftmost characters of panel function 13) of the reference
code 00000001?
- No:
- Go to the next step.
- Yes:
- Perform the following:
- The XYZ bus has an error. Replace the FRUs called out after this procedure.
- Did replacing the FRUs correct the problem?
- No:
- Perform the following:
- Replace the system backplane (Un-P1).
- Perform a slow boot. See Performing a slow boot . This ends
the procedure.
- Yes:
- This ends the procedure.
- Is word 6 of the reference code 00000002?
- No:
- Go to the next step.
- Yes:
- The AB bus has an error. Replace the FRUs called out after this procedure.
- Did replacing the FRUs correct the problem?
- No:
- Perform the following:
- Replace the system backplane (Un-P1).
- Perform a slow boot. See Performing a slow boot .
- Yes:
- This ends the procedure.
- Is word 6 of the reference code 00000004 or 00000005?
- No:
- Go to the next step.
- Yes:
- The processor - GX card bus or PSI bus has an error. Replace the FRUs
called out after this procedure.
- Did replacing the FRUs correct the problem?
- No:
- Perform the following:
- Replace the system backplane (Un-P1).
- Perform a slow boot. See Performing a slow boot . This ends
the procedure.
- Yes:
- This ends the procedure.
- For any other value in word 6 of the reference code, the bus error is
corrected by the FRUs called out after this procedure. Replace the FRUs called
out after this procedure. This ends the procedure.
8234-EMA, 9117-MMA, and 9406-MMA
Perform
the following task:
- Is word 6 (the 8 leftmost characters of panel function 13) of the reference
code 00000001 or 00000008?
- No:
- Go to the next step.
- Yes:
- Perform the following:
- The XYZ bus or the Processor - P5IOC2 bus has an error. Replace the FRUs
called out after this procedure.
- Did replacing the FRUs correct the problem?
- Yes:
- This ends the procedure.
- No:
- Perform the following:
- Replace the Regulator Distribution Backplane (Un-P2) from the drawer the
FRUs were replaced.
- Perform a slow boot. See Performing a slow boot . This ends
the procedure.
- Is word 6 of the reference code 00000002?
- No:
- Go to the next step.
- Yes:
- Perform the following:
- The AB bus has an error. Replace the SMP Cable (Un-P2-Cx-Tx is the connector
) between the FRUs called out after this procedure.
- Clear the deconfiguration errors for the FRUs called out.
- Perform a slow boot. See Performing a slow boot .
- Did replacing the SMP Cable correct the problem?
- No:
- Replace the FRUs called out after this procedure. This ends the procedure.
- Yes:
- This ends the procedure.
- Is word 6 of the reference code 00000004 or 00000005?
- No:
- Go to the next step.
- Yes:
- Perform the following:
- The processor - GX card bus or PSI bus has an error. Replace the FRUs
called out after this procedure.
- Did replacing the FRUs correct the problem?
- Yes:
- This ends the procedure.
- No:
- Perform the following:
- Replace the Regulator Distribution Backplane (Un-P2) from the drawer where
the FRUs were replaced.
- Perform a slow boot. See Performing a slow boot . This ends
the procedure.
- Does the problem persist?
- No:
- This ends the procedure.
- Yes:
- Perform the following:
- Replace the System Backplane (Un-P1) from the drawer where the FRUs were
replaced.
- Perform a slow boot. See Performing a slow boot . This ends
the procedure.
- Is word 6 of the reference code 00000006?
- No:
- Go to the next step.
- Yes:
- The DIMM - DIMM bus has an error. Replace the FRUs called out after this
procedure.
-
-
- Did replacing the FRUs correct the problem?
- No:
- Perform the following:
- Replace the Processor Card (Un-P2-C1 or Un-P2-C2) from the drawer where
the FRUs were replaced.
- Perform a slow boot. See Performing a slow boot . This ends
the procedure.
- Yes:
- This ends the procedure.
- For any other value in word 6 of the reference code, the bus error is
corrected by the FRUs called out after this procedure. Replace the FRUs called
out after this procedure. This ends the procedure.
9125-F2A- Is word 6 of the reference code 00000004?
- No:
- Go to the next step.
- Yes:
- The Processor-GX card bus has an error. Replace the FRUs called out after
this procedure.
- Did replacing the FRUs correct the problem?
- No:
- Perform the following:
- Replace the I/O Backplane (Un-P1)
- Perform a slow boot.
- Yes:
- This ends the procedure.
- Does the problem persist?
- No:
- This ends the procedure.
- Yes:
- For any other value in word 6 of the reference code, the bus error is
corrected by the FRUs called out after this procedure. Replace the FRUs called
out after this procedure. This ends the procedure.
9119-FHA- Is word 6 of the reference code 00000005 or 00000002?
- No:
- Go to step 3.
- Yes:
- The Processor AB or PSI card bus has an error. Replace the FRUs called
out after this procedure.
- Did replacing the FRUs correct the problem?
- No:
- Perform the following:
- Replace the system backplane (Un-P1).
- Perform a slow boot. This ends the procedure.
- Yes:
- This ends the procedure.
- Is word 6 of the reference code 00000006?
- No:
- Go to step 4.
- Yes:
- Perform the following:
- The DIMM - DIMM bus has an error. Replace the FRUs called out after this
procedure.
- Did replacing the FRUs correct the problem?
- No:
- Perform the following:
- Replace the Processor Book (Un-P2 thru P9) that the FRUs called out were
replaced on.
- Perform a slow boot. This ends the procedure.
- Yes:
- This ends the procedure.
- For any other value in word 6 of the reference code,
the bus error is corrected by the FRUs called out after this procedure. Replace
the FRUs called out after this procedure. This ends the procedure.