FSPSP62

The Service Processor has detected a missing node due to a mismatch between the nodes with power and what nodes the Service Processor can communicate with.

  1. Using the 9119–FHA bulk power connection tables or 9125–F2A bulk power connection tables, verify the cables for the missing node. Word 6 of the SRC identifies the missing node as follows:
    Table 1.
    Word 6 value Missing node
    0x0000000x ( x = 2 through 9) Node Controllers Un-Px (x = 2 through 9)
  2. Are the cables set correctly?
    Yes:
    Continue to step 4.
    No:
    Correct the cable connections. Perform a slow boot.
  3. Does the problem persist?
    Yes:
    Continue to the next step.
    No:
    This ends the procedure.
  4. Replace the cables used to connect the missing node to the bulk power hubs. Perform a slow boog.
  5. Does the problem persist?
    Yes:
    Continue to the next step.
    No:
    This ends the procedure.
  6. Replace the Node Controllers (Un-Px-C41 or Un-Px-C42, where x = word 6 value) on the missing node. Perform a slow boot. This ends the procedure.

9119–FHA bulk power connection tables

Contains four cross reference tables that identifies the CEC node to bulk power hub, system controller to bulk power hub, bulk power controller to bulk power hub, and Hardware Management Console (HMC) bulk power hub connections.

Table 2. Node controller to bulk power hub connection table
CEC Node Location FRU Location FRU Connector Location Bulk Power Hub (BPH) Side A Connector Location Bulk Power Hub (BPH) Side B Connector Location
Un refers to BPC location.
Um refers to CEC location.
P2 Um-P2-C41 Um-P2-C41-J01 Un-P1-C4-J18  
    Um-P2-C41-J02   Un-P1-C4-J18
  Um-P2-C42 Um-P2-C42-J01 Un-P1-C4-J17  
    Um-P2-C42-J02   Un-P2-C4-J17
P3 Um-P3-C41 Um-P3-C41-J01 Un-P1-C4-J12  
    Um-P3-C41-J02   Un-P1-C4-J12
  Um-P3-C42 Um-P3-C42-J01 Un-P1-C4-J11  
    Um-P3-C42-J02   Un-P2-C4-J11
P4 Um-P4-C41 Um-P4-C41-J01 Un-P1-C4-J10  
    Um-P4-C41-J02   Un-P1-C4-J10
  Um-P4-C42 Um-P4-C42-J01 Un-P1-C4-J09  
    Um-P4-C42-J02   Un-P2-C4-J09
P5 Um-P5-C41 Um-P5-C41-J01 Un-P1-C4-J22  
    Um-P5-C41-J02   Un-P1-C4-J22
  Um-P5-C42 Um-P5-C42-J01 Un-P1-C4-J21  
    Um-P5-C42-J02   Un-P2-C4-J21
P6 Um-P6-C41 Um-P6-C41-J01 Un-P1-C4-J20  
    Um-P6-C41-J02   Un-P1-C4-J20
  Um-P6-C42 Um-P6-C42-J01 Un-P1-C4-J19  
    Um-P6-C42-J02   Un-P2-C4-J19
P7 Um-P7-C41 Um-P7-C41-J01 Un-P1-C4-J16  
    Um-P7-C41-J02   Un-P1-C4-J16
  Um-P7-C42 Um-P7-C42-J01 Un-P1-C4-J15  
    Um-P7-C42-J02   Un-P2-C4-J15
P8 Um-P8-C41 Um-P8-C41-J01 Un-P1-C4-J14  
    Um-P8-C41-J02   Un-P1-C4-J14
  Um-P8-C42 Um-P8-C42-J01 Un-P1-C4-J13  
    Um-P8-C42-J02   Un-P2-C4-J13
P9 Um-P9-C41 Um-P9-C41-J01 Un-P1-C4-J24  
    Um-P9-C41-J02   Un-P1-C4-J24
  Um-P9-C42 Um-P9-C42-J01 Un-P1-C4-J23  
    Um-P9-C42-J02   Un-P2-C4-J23
Table 3. System controller to bulk power hub connection table
System controller (SC) FRU Location FRU Connector Location Bulk Power Hub (BPH) Side A Connector Location Bulk Power Hub (BPH) Side B Connector Location
SC-A Um-P1-C2 Um-P1-C2-J04 Un-P1-C4-J05  
    Um-P1-C2-J03   Un-P2-C4-J05
SC-B Um-P1-C5 Um-P1-C5-J04 Un-P1-C4-J06  
    Um-P1-C5-J03   Un-P2-C4-J06
Table 4. Bulk power controller to bulk power hub connection table
Bulk Power Controller (BPC) FRU Location FRU Connector Location Bulk Power Hub (BPH) Side A Connector Location Bulk Power Hub (BPH) Side B Connector Location
BPC-A Un-P1-C1 Un-P1-C2-J02 Un-P1-C4-J07  
    Un-P1-C2-J03   Un-P2-C4-J07
BPC-B Un-P2-C1 Un-P1-C5-J02 Un-P1-C4-J08  
    Un-P1-C5-J03   Un-P2-C4-J08
Table 5. Hardware management console (HMC) bulk power hub connection table
HMC Bulk Power Hub (BPH) Side A Connector Location Bulk Power Hub (BPH) Side B Connector Location
HMC-A Un-P1-C4-J01  
HMC-B   Un-P2-C4-J01

9125–F2A bulk power connection tables

Contains two cross reference tables that identifies the CEC node to bulk power hub and the bulk power controller to bulk power hub connections.

Table 6. CEC node to bulk power hub connection table
CEC Node Location FRU Location FRU Connector Location Bulk Power Hub (BPH) Side A Connector Location Bulk Power Hub (BPH) Side B Connector Location
Un refers to BPC location.
01–17 refers to CEC node frame location.
(01) U01-P1 U01-P1-T10 Un-P1-C4-J24  
    U01-P1-T11   Un-P2-C4-J24
(02) U03-P1 U03-P1-T10 Un-P1-C4-J23  
    U03-P1-T11   Un-P2-C4-J23
(03) U05-P1 U05-P1-T10 Un-P1-C4-J22  
  U05-P1-T11   Un-P2-C4-J22
(04) U07-P1 U07-P1-T10 Un-P1-C4-J21  
    U07-P1-T11   Un-P2-C4-J21
(05) U09-P1 U09-P1-T10 Un-P1-C4-J20  
    U09-P1-T11   Un-P2-C4-J20
(06) U11-P1 U11-P1-T10 Un-P1-C4-J19  
    U11-P1-T11   Un-P2-C4-J19
(07) U13-P1 U13-P1-T10 Un-P1-C4-J18  
    U13-P1-T11   Un-P2-C4-J18
(08) U15-P1 U15-P1-T10 Un-P1-C4-J17  
    U15-P1-T11   Un-P2-C4-J17
(09) U17-P1 U17-P1-T10 Un-P1-C4-J16  
    U17-P1-T11   Un-P2-C4-J16
(10) U19-P1 U19-P1-T10 Un-P1-C4-J15  
    U19-P1-T11   Un-P2-C4-J15
(11) U21-P1 U21-P1-T10 Un-P1-C4-J14  
    U21-P1-T11   Un-P2-C4-J14
(12) U23-P1 U23-P1-T10 Un-P1-C4-J13  
    U23-P1-T11   Un-P2-C4-J13
(13) U25-P1 U25-P1-T10 Un-P1-C4-J12  
    U25-P1-T11   Un-P2-C4-J12
(14) U27-P1 U27-P1-T10 Un-P1-C4-J11  
    U27-P1-T11   Un-P2-C4-J11
(15) U29-P1 U29-P1-T10 Un-P1-C4-J10  
    U29-P1-T11   Un-P2-C4-J10
(16) U31-P1 U31-P1-T10 Un-P1-C4-J09  
    U31-P1-T11   Un-P2-C4-J09
Table 7. Bulk power controller to bulk power hub connection table
Bulk Power Controller (BPC) FRU Location FRU Connector Location Bulk Power Hub (BPH) Side A Connector Location Bulk Power Hub (BPH) Side B Connector Location
BPC-A Un-P1-C1 Un-P1-C2-J02 Un-P1-C4-J07  
    Un-P1-C2-J03   Un-P2-C4-J07
BPC-B Un-P2-C1 Un-P1-C5-J02 Un-P1-C4-J08  
    Un-P1-C5-J03   Un-P2-C4-J08