Use this procedure to isolate problems with station protectors.
Station protectors must be installed on all twinaxial cables that
leave the building in which the server is located. This applies even if the
cables go underground, through a tunnel, through a covered outside hallway,
or through a skyway. Station protectors help prevent electrical noise on these
cables from affecting the server.
- Look at the Product Activity Log to determine what workstations
are associated with the failure.
- Determine if station protectors are installed on the twinaxial
cables to the failing workstations.
Are station protectors installed
on the twinaxial cables to the failing workstations?
- Yes: Perform the next intermittent isolation procedure listed
in the Isolation procedure column. This ends the procedure.
- No: You may need to install station protectors on the twinaxial
cables to the failing workstations. This ends the procedure.