Use this procedure to collect data when the service processor reports
a suspected intermittent problem.
It is important that you collect data for this problem so that
the problem can be corrected. Use this procedure to collect the data.
There
are several ways the system can display the SRC. Follow the instructions for
the correct display method, defined as follows:
- If this SRC is displayed in the Product Activity Log or ASM log, then
record all of the SRC data words, save all of the error log data, and contact
your next level of support to submit an APAR.
- If the control panel is displaying SRC data words scrolling automatically
through control panel functions 11, 12 and 13, and the control panel user
interface buttons are not responding, then perform FSPSP02 instead
of using this procedure.
- If the SRC is displayed at the control panel, and the control panel user
interface buttons respond normally, then record all of the SRC words.
Do not perform an IPL until you perform a storage dump of the service
processor. To get a storage dump of the service processor, perform the following: