Use this procedure to isolate the problem when a storage I/O adapter
is connected to an incompatible or non-operational auxiliary cache I/O adapter.
- Are you working on a 571F/575B combination storage
and auxiliary cache IOA card set (uses two card slot locations)?
- Yes: Continue with step 2.
- No: Continue with step 3.
- Find the location of
the card.
- Use the location displayed in the Service Action Log. If the Service Action
Log does not have a location, determine the address of the I/O adapter. See System
Reference Code (SRC) Format Description .
- The location identified is for the 571F side of the card set.
You must configure both the 571F and the 575B in the same partition.
Are both the 571F side of the card set and the 575B side of the card set configured
in the same partition?- Yes: Replace the entire card set. See System FRU locations for information
on FRU locations on the system that you are servicing. This ends the procedure.
- No: Change the configuration so that the same partition controls
both cards in the card set. This ends the procedure.
- Ensure that the SCSI cable on the last port
of the storage I/O adapter is connected to the auxiliary cache I/O adapter. Do the following:
- Use the location of the storage I/O adapter displayed in the
Service Action Log. If the Service Action Log does not have a location,
determine the address of the storage I/O adapter. See System
Reference Code (SRC) Format Description .
- Determine the location of the storage I/O adapter. See
System FRU locations for information
on FRU locations on the system that you are servicing.
- Ensure that the SCSI cable on the last port of the storage I/O
adapter is properly connected to an auxiliary cache I/O adapter.
- Ensure that both the auxiliary cache I/O adapter
and the storage I/O adapter are in the same partition.
- Ensure that the slot power indicator is lit for the auxiliary
cache I/O adapter. If it is not, use concurrent maintenance to
power on the slot.
- Ensure that the auxiliary cache I/O adapter is supported for the
storage I/O adapter to which it is connected. See the PCI adapter
installation instructions for information about which adapters are compatible.
- Replace the SCSI cable on the last port of the storage I/O adapter
that connects to the auxiliary cache I/O adapter. See System FRU
locations for information
on FRU locations on the system that you are servicing. If this does not fix
the problem, replace the auxiliary cache I/O adapter. This ends the procedure.