This procedure will isolate a failing PCI adapter from a reference
code when an IPL is not successful on the system or logical partition.
Attention: The removal and replacement procedure of all
FRUs in this procedure are performed using dedicated maintenance (partition
powered off). If not, the problem cannot be fixed.
- Determine the PCI bridge set (multi-adapter bridge domain) by performing
the following:
- Record the bus number (BBBB), the multi-adapter
bridge number (C) and the multi-adapter bridge function number
(c) from the Direct Select Address (DSA) in word 7 of the
reference code. See DSA translation for
help in determining these values.
- Use the bus number that you recorded and the System Configuration
Listing (or ask the customer) to determine what frame the bus is in.
- Record the frame type where the bus is located.
- Use the System Configuration Listing, the card
position table for the frame type that you recorded, the bus number,
and the multi-adapter bridge number to determine the PCI bridge set where
the failure occurred. The PCI bridge set is the group of card positions
controlled by the same multi-adapter bridge on the bus that you recorded.
- Use the card position table to
record the PCI bridge set card positions.
- Examine the PCI bridge set in the frame, and record all the
positions with IOA cards installed in them.
- Perform the following:
- Power off the partition.
- Remove all the IOA cards in the PCI bridge set identified in
step 1. Be sure to record the card position of each IOA so that
you can reinstall it in the same position later. To determine the location
of all the IOA cards in the PCI bridge set, go to System FRU locations .
- Power on the partition.
Does the reference code
or failure that sent you to this procedure occur?
- No:
- Continue with the next step.
- Yes:
- The problem is the multi-adapter bridge. Continue with step MABIP52.
- Reinstall one of the IOAs and power on the partition. Does the
reference code or failure that sent you to this procedure occur?
- Yes:
- The IOA that you just installed is the failing FRU. Replace the IOA.This
ends the procedure.
- No:
- If a different SRC occurs, return to Start of Call and follow the service
procedures for the new reference code. This ends the procedure.
- If no SRC occurs and there are more IOAs to install, power off the partition
and repeat this step.
- If no SRC occurs and there are no more IOAs to install, the problem is
intermittent; contact your next level of support. This ends the procedure.
- Power off the partition. Determine which FRU
contains the multi-adapter bridge. Locate the card
position table for the frame type that you recorded. Perform the following:
- Using the multi-adapter bridge number that you recorded, search
for the multi-adapter bridge function number "F" in the card position table
to determine the card position of the multi-adapter bridge's FRU.
- Exchange the multi-adapter bridge's FRU at the card position
that you determined for it. See System FRU locations to determine the
correct card location for removal.
- Install all IOAs in their original positions.
- Power on the partition.
Does the reference code or failure that sent you to this procedure
occur?
- No:
- Go to Verify a repair . This ends
the procedure.
- Yes:
- Call your next level of support. This ends the procedure.