Use this procedure to isolate the failing PCI I/O adapter card
from a reference code with a Direct Select Address when the serviceable event
view does not indicate a location for the PCI card.
The removal and replacement of all FRUs in
this procedure must be performed using dedicated maintenance.
- Is the partition an AIX® partition or a Linux® partition,
or is an HMC attached?
- No:
- Continue with the next step.
- Yes:
- Go to PCI bus isolation using AIX, Linux, or the HMC to isolate a PCI bus
problem from AIX, Linux,
or the HMC.
- Determine the PCI bridge set (multi-adapter bridge domain) by performing
the following:
- Record the bus number (BBBB), the multi-adapter bridge number (C), and
the multi-adapter bridge function number (c) from the Direct Select Address
(DSA) (see Analyzing a RIO/HSL/12X or PCI bus reference code for help in determining
these values).
- Using the bus number and the System Configuration Listing, or by asking
the customer, determine which unit the bus is located in and record that unit
type.
- The PCI bridge set is the group of card positions controlled by the same
multi-adapter bridge on the bus that you recorded. Use the System Configuration
Listing, the Card positions table for the unit
type that you recorded, the bus number, and the multi-adapter bridge number
to determine in which PCI bridge set the failure occurred.
- Using the card position table, record the PCI bridge set card positions,
and the multi-adapter bridge function numbers.
- Examine the PCI bridge set and record the information on the form for
all of the positions with IOP and IOA cards installed in them.
- Perform the following:
- Power off the system or partition.
- Remove all the IOAs in the PCI bridge set identified in step 1. Be sure
to record the card position of each IOA so that you can reinstall it in the
same position later. To determine the remove and replace procedures for the
IOAs, locate the IOA card positions in System FRU locations for the frame
type that you recorded.
- Power on the system or partition.
Does the reference code or failure that sent you to this procedure occur?- No: Power off the system or partition. Go to step 7.
- Yes: Continue with the next step.
- Perform the following:
- Power off the system or partition.
- Exchange the IOP that is indicated in the DSA. Be sure to record the card
position of the IOP so that you can reinstall it in the same position later.
To determine the exchange procedure for the IOP, locate the IOP's card position
in System FRU locations for the frame
type you recorded.
- Power on the system or partition.
Does the reference code or failure that sent you to this procedure occur?- No: Power off the system or partition. Go to step 11.
- Yes: Continue with the next step.
- Perform the following:
- Power off the system or partition.
- Install all of the IOAs that you removed in step 2. Be sure to install
them in their original positions.
- Power on the system or partition.
Does the reference code or failure that sent you to this procedure occur?
- Perform the following:
- Power off the system or partition.
- Remove all of the IOAs in the PCI bridge set identified in step 1. Be
sure to record the card position of each IOA so that you can reinstall it
in the same position later.
- Remove the IOP that you exchanged and install the original IOP in its
original position. Continue with the next step.
- Perform the following:
- Reinstall, in its original position, one of the IOAs that you removed.
- Power on the system or partition.
Does the reference code or failure that sent you to this procedure occur?- No: Power off the system or partition. Repeat this step for another
one of the IOAs that you removed. If you have reconnected all of the IOAs
and the reference code or failure that sent you to this procedure does not
occur, the problem is intermittent; contact your next level of support. This
ends the procedure.
- Yes: The IOA that you just installed is the failing FRU. Continue
with the next step.
- Perform the following:
- Power off the system or partition.
- Replace the I/O adapter card that you last installed. Be sure to install
the new I/O adapter card in the same position.
- Power on the system or partition.
Does the reference code or failure that sent you to this procedure occur?- Yes: Contact your next level of support. This ends the procedure.
- No: Continue with the next step.
- Perform the following:
- Power off the system or partition.
- Reinstall, in their original positions, the remaining I/O adapter cards
that you removed.
- Power on the system or partition.
Does the reference code or failure that sent you to this procedure occur?- Yes: Contact your next level of support. This ends the procedure.
- No: Continue with the next step.
- Does a different reference code occur?
- The problem is the multi-adapter bridge. Perform the
following:
- Power off the system or partition.
- If you have not already done so, replace the I/O backplane in the failing
enclosure.
- Install the original IOP in its original position.
- Install all of the other IOPs and IOAs into their original positions.
Do not install the IOAs that you were instructed to remove in step 3.
- Power on the system or partition.
Does the reference code or failure that sent you to this
procedure occur?- Yes: Contact your next level of support. This ends the procedure.
- No: Continue with the next step.
- Perform the following:
- Power off the system or partition.
- Install all of the IOAs that you removed in step 3.
Be sure to install them in their original positions.
- Power on the system or partition.
Does the reference code or failure that sent you to this procedure occur?- Yes: Contact your next level of support. This ends the procedure.
- No: The problem has been resolved. This ends the procedure.