These procedures help you to isolate a failure with the Operations
Console.
When working on or around the system,
observe the following precautions:
Electrical voltage and current
from power, telephone, and communication cables are hazardous. To
avoid a shock hazard:
- Connect power to this unit only with the IBM provided
power cord. Do not use the IBM provided power
cord for any other product.
- Do not open or service any power supply assembly.
- Do not connect or disconnect any cables or perform installation,
maintenance, or reconfiguration of this product during an electrical
storm.
- The product might be equipped with multiple power cords. To remove
all hazardous voltages, disconnect all power cords.
- Connect all power cords to a properly wired and grounded electrical
outlet. Ensure that the outlet supplies proper voltage and phase
rotation according to the system rating plate.
- Connect any equipment that will be attached to this product to
properly wired outlets.
- When possible, use one hand only to connect or disconnect signal
cables.
- Never turn on any equipment when there is evidence of fire, water,
or structural damage.
- Disconnect the attached power cords, telecommunications systems,
networks, and modems before you open the device covers, unless instructed
otherwise in the installation and configuration procedures.
- Connect and disconnect cables as described in the following procedures
when installing, moving, or opening covers on this product or attached
devices.
To Disconnect:
- Turn off everything (unless instructed otherwise).
- Remove the power cords from the outlets.
- Remove the signal cables from the connectors.
- Remove all cables from the devices
To Connect:
- Turn off everything (unless instructed otherwise).
- Attach all cables to the devices.
- Attach the signal cables to the connectors.
- Attach the power cords to the outlets.
- Turn on the devices.
(D005)
For direct cable only
The following
symptoms can be caused by Operations Console failing to connect:
- SRC A600 5008
- The status in the Operations Console window remains "Connecting console".
The following symptoms can be caused by a defective remote control
panel cable:
- Remote control panel (hung) System control panel functions.
- SRC 0000 DDDD with attention light on the system panel.
- Remote control panel accepts mode selections, however the system does
not respond.
- The remote control panel does not function.
- The status in the Operations Console window remains "Connecting console".
The following safety notices apply throughout this section.
Read
all safety procedures before servicing the system. Observe all safety procedures
when performing a procedure. Unless instructed otherwise, always power off
the system or expansion tower where the field-replaceable unit (FRU) is located
before removing, exchanging, or installing a FRU.